View All

Please refer to the English Version as our Official Version.Return

Europe
France(Français) Germany(Deutsch) Italy(Italia) Russian(русский) Poland(polski) Czech(Čeština) Luxembourg(Lëtzebuergesch) Netherlands(Nederland) Iceland(íslenska) Hungarian(Magyarország) Spain(español) Portugal(Português) Turkey(Türk dili) Bulgaria(Български език) Ukraine(Україна) Greece(Ελλάδα) Israel(עִבְרִית) Sweden(Svenska) Finland(Svenska) Finland(Suomi) Romania(românesc) Moldova(românesc) Slovakia(Slovenská) Denmark(Dansk) Slovenia(Slovenija) Slovenia(Hrvatska) Croatia(Hrvatska) Serbia(Hrvatska) Montenegro(Hrvatska) Bosnia and Herzegovina(Hrvatska) Lithuania(lietuvių) Spain(Português) Switzerland(Deutsch) United Kingdom(English)
Asia/Pacific
Japan(日本語) Korea(한국의) Thailand(ภาษาไทย) Malaysia(Melayu) Singapore(Melayu) Vietnam(Tiếng Việt) Philippines(Pilipino)
Africa, India and Middle East
United Arab Emirates(العربية) Iran(فارسی) Tajikistan(فارسی) India(हिंदी) Madagascar(malaɡasʲ)
South America / Oceania
New Zealand(Maori) Brazil(Português) Angola(Português) Mozambique(Português)
North America
United States(English) Canada(English) Haiti(Ayiti) Mexico(español)
HomeProductsCircuit ProtectionCircuit BreakersIEGF6-1REC4-31372-15-V
Image may be representation.
See specifications for product details.
EXPRESS OPTION
Payment method

IEGF6-1REC4-31372-15-V - Sensata-Airpax

Manufacturer Part Number
IEGF6-1REC4-31372-15-V
Manufacturer
Airpax / Sensata Technologies
Allelco Part Number
98D-IEGF6-1REC4-31372-15-V
Warranty
1 Year Allelco Warranty - Find out more
Stock Status:
37,637 pcs available, New & Original
Parts Description
CIR BRKR MAG-HYDR LEVER
Package
Bulk
Data sheet
IEGF6-1REC4-313.pdf
RoHs Status
RoHS Compliant
Our certification
In stock: 37637

Required fields are indicated by an asterisk (*)
Please send RFQ, we will respond immediately.

Quantity

Specifications

IEGF6-1REC4-31372-15-V Tech Specifications
Sensata-Airpax - IEGF6-1REC4-31372-15-V technical specifications, attributes, parameters and parts with similar specifications to Sensata-Airpax - IEGF6-1REC4-31372-15-V

Product Attribute Attribute Value
Manufacturer Airpax / Sensata Technologies
Series IEG
Package Bulk
Number of Poles 1
Mounting Type Panel Mount
Illumination Voltage (Nominal) -
Product Attribute Attribute Value
Illumination -
Current Rating (Amps) -
Breaker Type Magnetic (Hydraulic Delay)
Base Product Number IEGF6
Approval Agency CSA, TUV, UL1077
Actuator Type Lever

Environmental & Export Classifications

ATTRIBUTE DESCRIPTION
RoHs Status RoHS Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited)
ECCN EAR99
HTSUS 8536.20.0020

Frequently Asked Questions(FAQ)

What are the key performance differences between IEGF6-1REC4-31372-15-V and standard thermal-magnetic circuit breakers in industrial motor control applications?
The IEGF6-1REC4-31372-15-V employs a magnetic (hydraulic delay) tripping mechanism, which provides faster response to high-current faults compared to purely thermal-magnetic breakers that rely on bimetallic strip heating. This design enables precise coordination in motor circuits where transient surges are common, reducing nuisance tripping while maintaining protection against sustained overcurrents. Unlike standard thermal breakers, the hydraulic delay allows the breaker to withstand brief overloads without interruption, improving system availability in manufacturing environments.
How does the panel mount configuration of the IEGF6-1REC4-31372-15-V impact installation and maintenance workflows in rack-based power distribution systems?
The panel mount design facilitates secure integration into standardized backplanes and enclosures, enabling easy access during maintenance without requiring full system shutdown. Its lever actuator allows manual operation for testing or isolation, which is particularly valuable in field service scenarios. However, proper torque specification during mounting is critical due to the mechanical linkage involved in the hydraulic delay mechanism, as misalignment can affect tripping accuracy and long-term reliability.
What environmental and regulatory considerations must be evaluated when selecting the IEGF6-1REC4-31372-15-V for use in North American versus European industrial installations?
While the IEGF6-1REC4-31372-15-V is UL1077 and CSA certified, indicating compliance with North American safety standards, its TUV approval supports deployment in Europe under IEC 60947-2 guidelines. Designers should verify whether local regulations require additional certifications such as CE marking or conformity to specific low-voltage directives. The RoHS compliant status ensures lead-free construction, meeting global environmental requirements, but regional variations in hazardous substance reporting may still apply.
Can the IEGF6-1REC4-31372-15-V be used interchangeably with similar-rated breakers from other manufacturers in existing control panels without redesign?
Interchangeability depends on dimensional compatibility, terminal spacing, and mounting hardware alignment. Although the base product number IEGF6 suggests a family with shared form factors, slight variations in housing tolerances or actuator geometry between vendors may prevent direct substitution. Engineers should validate physical fit and electrical continuity before replacement, especially in legacy systems where space constraints limit modification options.
How does the moisture sensitivity level (MSL) classification of MSL 1 influence storage and handling procedures for bulk shipments of IEGF6-1REC4-31372-15-V components?
With an MSL rating of 1, the IEGF6-1REC4-31372-15-V is not subject to shelf-life limitations or humidity exposure warnings, allowing indefinite storage under normal ambient conditions. This simplifies inventory management for long-term projects but does not eliminate the need for proper ESD precautions during assembly due to internal semiconductor elements in associated monitoring circuits.
What trade-offs exist between using the IEGF6-1REC4-31372-15-V and solid-state current limiters in precision instrumentation power supplies?
The IEGF6-1REC4-31372-15-V offers robust mechanical protection with predictable trip curves suitable for fault isolation in harsh environments, whereas solid-state limiters provide faster response and no moving parts. However, solid-state devices may introduce electromagnetic interference and have limited energy absorption capacity. For applications requiring galvanic isolation and high surge tolerance, the IEGF6-1REC4-31372-15-V remains advantageous despite slower actuation speed.
In what scenarios would the single-pole configuration of the IEGF6-1REC4-31372-15-V be insufficient for protecting three-phase motor loads?
A single-pole breaker like the IEGF6-1REC4-31372-15-V protects only one conductor, making it inadequate for full three-phase motor protection unless paired with additional poles or used in conjunction with phase-loss relays. Using it alone risks unbalanced operation and incomplete fault coverage. Proper implementation requires either a three-pole unit or coordination with supplementary protective relays to monitor all phases.
How does the hydraulic delay mechanism in the IEGF6-1REC4-31372-15-V affect coordination with downstream fuses or contactors in a time-current curve application?
The hydraulic delay allows the IEGF6-1REC4-31372-15-V to tolerate brief inrush currents common in inductive loads, creating a "hump" in its time-current characteristic. When coordinating with fast-acting fuses, engineers must ensure the fuse clears faults faster than the breaker’s hydraulic response to avoid unnecessary interruption of non-fault conditions. Selective coordination studies should account for this behavior to maintain system stability during startup transients.
What impact do variations in supply voltage ripple have on the tripping accuracy of the IEGF6-1REC4-31372-15-V in variable frequency drive (VFD)-powered systems?
As a magnetic-hydraulic breaker, the IEGF6-1REC4-31372-15-V responds primarily to current magnitude rather than voltage anomalies. However, significant voltage sags or harmonics generated by VFDs may indirectly affect load current profiles, potentially triggering false trips if harmonic content increases RMS current beyond threshold levels. Proper filtering or use of current-limiting reactors can mitigate such interactions without compromising protection integrity.
Why might the absence of illumination in the IEGF6-1REC4-31372-15-V be a limitation in diagnostic-intensive environments?
Without built-in status indication, determining the operational state of the IEGF6-1REC4-31372-15-V—whether tripped, closed, or open—requires visual inspection of the lever position. In dark or remote locations, this complicates troubleshooting. Engineers often supplement such breakers with external pilot lights or IoT-enabled sensors to enhance visibility, adding complexity but improving maintainability.
How does the ECCN designation EAR99 influence procurement and export considerations for the IEGF6-1REC4-31372-15-V in international supply chains?
Classified under EAR99, the IEGF6-1REC4-31372-15-V falls under U.S. export administration regulations requiring minimal licensing for most destinations. This simplifies global sourcing and reduces bureaucratic overhead for commercial buyers. However, end-use verification is still recommended to ensure compliance with final destination restrictions, particularly in defense or aerospace sectors.
What role does the HTSUS code 8536.20.0020 play in customs classification and duty assessment for imported units of IEGF6-1REC4-31372-15-V?
This Harmonized Tariff Schedule code categorizes the IEGF6-1REC4-31372-15-V as an automatic circuit breaker for AC use, facilitating accurate import documentation and duty calculation in U.S. customs processing. Accurate classification helps prevent delays at ports of entry and ensures compliance with trade agreements affecting component tariffs across regions.
How does the lever actuator type compare functionally to toggle or rocker actuators in terms of mechanical durability and user feedback during repeated operations?
The lever actuator of the IEGF6-1REC4-31372-15-V provides clear tactile feedback and a distinct ON/OFF position, enhancing operator confidence in field settings. Compared to toggles, levers offer better resistance to accidental actuation under vibration; however, they require more physical space. Rocker types save footprint but may lack positional clarity. For industrial panels with frequent access, the lever’s robustness and intuitive operation make it favorable despite size constraints.
What considerations apply when integrating the IEGF6-1REC4-31372-15-V into a fail-safe control architecture requiring redundant protection layers?
Since the IEGF6-1REC4-31372-15-V is not inherently self-diagnosing, redundancy must include independent monitoring such as current sensors or supervisory logic to detect stuck contacts. In safety-critical systems, functional safety standards like ISO 13849 may require dual-channel architectures where the IEGF6-1REC4-31372-15-V operates alongside another protective device with cross-verification capability.
How does the absence of specified current rating in the provided data affect selection for a 24V DC servo motor circuit drawing 12A continuous current?
The missing current rating suggests the IEGF6-1REC4-31372-15-V may belong to a broader series where ratings are selected via suffix codes. Engineers should consult the full Sensata-Airpax IEGF6 datasheet to identify variants rated near 12A with appropriate interrupting capacity. Oversizing slightly (e.g., 15A class) can accommodate inrush while avoiding nuisance trips, but derating for ambient temperature and altitude is essential for reliable operation.
What are the implications of using the IEGF6-1REC4-31372-15-V in a marine environment with high salt spray exposure?
While the breaker itself is not sealed against environmental ingress, standard enclosures with NEMA 4X ratings can protect it from corrosion. The aluminum or zinc-plated housing materials typically used in the IEGF6 series resist moderate salt exposure, but long-term immersion or aggressive cleaning chemicals may accelerate degradation. Regular inspection intervals should be factored into maintenance planning to preserve contact integrity.
How does the base product number IEGF6 relate to derivative models, and how can designers ensure compatibility when scaling designs across multiple projects?
The IEGF6 prefix indicates a product family sharing core mechanical and electrical characteristics. Derivatives differ mainly in current rating, frame size, and certifications. Designers should reference Sensata’s master part list to map suffixes to specifications, ensuring consistent performance across revisions. Avoiding hard-coded references to specific part numbers in schematics improves flexibility during obsolescence management.
In what ways does the hydraulic delay feature differentiate the IEGF6-1REC4-31372-15-V from pure electromagnetic breakers in terms of energy dissipation during fault events?
The hydraulic delay uses viscous fluid damping to absorb kinetic energy from the tripping spring, slowing the contact separation and reducing arcing duration. This contrasts with pure electromagnetic breakers, which act instantaneously and generate higher transient voltages. The IEGF6-1REC4-31372-15-V’s controlled response lowers arc flash risk and extends contact life, benefiting systems with sensitive downstream electronics.

Parts with Similar Specifications

The three parts on the right have similar specifications to Sensata-Airpax IEGF6-1REC4-31372-15-V

Product Attribute IEGF6-1REC4-31372-10-V IEGF6-1REC4-31372-5-V IEGF6-1REC4-31372-2-V IEGF6-1REC4-31372-20-V
Part Number IEGF6-1REC4-31372-10-V IEGF6-1REC4-31372-5-V IEGF6-1REC4-31372-2-V IEGF6-1REC4-31372-20-V
Manufacturer Sensata-Airpax Sensata-Airpax Sensata-Airpax Sensata-Airpax
Approval Agency - - - -
Series - - - -
Current Rating (Amps) - - - -
Illumination Voltage (Nominal) - - - -
Breaker Type - - - -
Package - Tape & Reel (TR) Tube Tape & Reel (TR)
Number of Poles - - - -
Mounting Type - Surface Mount Through Hole Surface Mount
Base Product Number - DAC34H84 MAX500 ADS62P42
Actuator Type - - - -
Illumination - - - -

IEGF6-1REC4-31372-15-V Datasheet PDF

Download IEGF6-1REC4-31372-15-V pdf datasheets and Sensata-Airpax documentation for IEGF6-1REC4-31372-15-V - Sensata-Airpax.

Datasheets
Cylindrical Battery Holders.pdf

Customer Reviews

Evaluation: 10 Articles

  • Nord***mbedded
    Jul 20, 2026

    Reliable FPGA with predictable behavior. Configuration and testing went smoothly, making development faster than expected.

  • Arch***ct
    Jul 15, 2026

    Used this device in a communication signal processing board. Stable timing and no unexpected issues during implementation.

  • FPGA***lorer88
    Jul 7, 2026

    The FPGA works properly and all functions operate as expected. Documentation required some additional research, but overall it is a usable device for smaller signal processing projects.

  • Nath***oleman
    Jun 29, 2026

    Used this sensor component in an industrial automation setup. Detection accuracy was consistent and installation was straightforward.

  • Emil***rperTech
    Jun 23, 2026

    Works exactly as described. I used it as a USB-to-SPI bridge in a small MCU development project and communication was stable from the first setup.

  • Liam***terTech
    Jun 15, 2026

    Used this CPLD in a logic control project. Programming was straightforward and signal timing matched the design requirements.

  • Nath***rooks
    Jun 11, 2026

    Installed this power component in a converter board. Output remained stable under different load conditions and thermal performance was better than expected.

  • Dani***alkerTech
    Jun 1, 2026

    Product works, but setup took more effort than expected. Once configured the MCU ran reliably, although documentation support felt older compared with newer platforms. Fine for maintenance projects.

  • Yuki***aka88
    May 26, 2026

    信号通信プロジェクトでこのRS-485トランシーバーを使用しました。設置は簡単で、長距離ケーブルでも通信は安定していました。消費電力も、以前使用していたものより低くなっています。

  • Stev***aker
    May 20, 2026

    Solid diode for power rectification. Works well in switching circuits.

Write a Review

Your Email address will not be published.

Shipment

Delivery Time

In-stock items can be shipped within 24 hours. Some parts will be arranged for delivery within 1-2 days from the date all items arrive at our warehouse. And Allelco ships order once a day at about 17:00, except Sunday. Once the goods are shipped, the estimated delivery time depends on the shipping methods and Delivery destination. The table below shows are the logistic time for some common countries.

Delivery Cost

  1. Use your express account for shipment if you have one.
  2. Use our account for the shipment. Refer to the table below for the approximate charges.
(Different time frame / countries / package size has different price.)

Delivery Method

  1. Global Common Shipment by DHL / UPS / FedEx / TNT / EMS / SF we support.
  2. Others more shipping ways, please get in touch with your customer manager.

Common Countries Logistic Time Reference
Region Country Logistic Time(Day)
America United States 5
Brazil 7
Europe Germany 5
United Kingdom 4
Italy 5
Oceania Australia 6
New Zealand 5
Asia India 4
Japan 4
Middle East Israel 6
DHL & FedEx Shipment Charges Reference
Shipment charges(KG) Reference DHL(USD$)
0.00kg-1.00kg USD$30.00 - USD$60.00
1.00kg-2.00kg USD$40.00 - USD$80.00
2.00kg-3.00kg USD$50.00 - USD$100.00
Note:
The above table is for reference only. There may have some data bias for the uncontrollable factors.
Contact us if you have any questions.
  • QC (Quality Warranty)
  • Payment Support
  • Packaging
  • Certifications & Memberships

QC (Quality Warranty)

Allelco is committed to exceeding customer expectations through customer service excellence, order accuracy, and on-time delivery.
This is achieved through our commitment to the continual improvement of our processes, services, and products.


Strict quality inspection builds a solid foundation for electronic component quality.
  1. Visual inspection
  2. Performance testing and reliability verification
  3. Standardized full-process testing
  4. Precise control of every parameter
We eliminate defective components and ensure the stable operation of electronic devices through professional quality standards.

Payment Support

The payment method can be chosen from the methods shown below: Wire Transfer (T/T, Bank Transfer), Western Union, Credit card, PayPal.
  • HKBea
  • Paypal
  • MasterCard
  • Western-Union
  • VISA
Stable Delivery, Sincere Partnership — Your Faithful Supply Chain Partner
  • Efficient Supply Management
  • Cost-Saving Procurement
  • Fast Sourcing & Delivery
Contact us if you have any questions.

Packaging

Electrostatic Discharge Protection and Handling

All electrostatic-sensitive components are handled in accordance with electrostatic discharge control procedures. The products are hermetically sealed in anti-static safe packaging to prevent electrostatic damage. Appropriate labeling is also applied for identification and traceability. This ensures product integrity during storage, handling and transportation.


ESD

Certifications & Memberships

Third-party certified, strict quality control. Our certification
  • ISO 9001: 2015
  • ISO 13485: 2016
  • ISO 14001: 2015
  • ISO 28000: 2007
  • ISO 45001: 2018
  • GB/T 27922-2011
  • SMTA
  • IPC
  • ESD
  • PSMA
Sensata-Airpax

IEGF6-1REC4-31372-15-V

Sensata-Airpax
98D-IEGF6-1REC4-31372-15-V

Want a better price? Add to Cart and Submit RFQ now, we'll contact you immediately.

0 RFQ
Shopping cart (0 Items)
It is empty.
Compare List (0 Items)
It is empty.
Feedback

Your feedback matters! At Allelco, we value the user experience and strive to improve it constantly.
Please share your comments with us via our feedback form, and we'll respond promptly.
Thank you for choosing Allelco.

Subject
E-mail
Comments
Captcha
Drag or click to upload file
Upload File
types: .xls, .xlsx, .doc, .docx, .jpg, .png and .pdf.
Max file size: 10MB