View All

Please refer to the English Version as our Official Version.Return

Europe
France(Français) Germany(Deutsch) Italy(Italia) Russian(русский) Poland(polski) Czech(Čeština) Luxembourg(Lëtzebuergesch) Netherlands(Nederland) Iceland(íslenska) Hungarian(Magyarország) Spain(español) Portugal(Português) Turkey(Türk dili) Bulgaria(Български език) Ukraine(Україна) Greece(Ελλάδα) Israel(עִבְרִית) Sweden(Svenska) Finland(Svenska) Finland(Suomi) Romania(românesc) Moldova(românesc) Slovakia(Slovenská) Denmark(Dansk) Slovenia(Slovenija) Slovenia(Hrvatska) Croatia(Hrvatska) Serbia(Hrvatska) Montenegro(Hrvatska) Bosnia and Herzegovina(Hrvatska) Lithuania(lietuvių) Spain(Português) Switzerland(Deutsch) United Kingdom(English)
Asia/Pacific
Japan(日本語) Korea(한국의) Thailand(ภาษาไทย) Malaysia(Melayu) Singapore(Melayu) Vietnam(Tiếng Việt) Philippines(Pilipino)
Africa, India and Middle East
United Arab Emirates(العربية) Iran(فارسی) Tajikistan(فارسی) India(हिंदी) Madagascar(malaɡasʲ)
South America / Oceania
New Zealand(Maori) Brazil(Português) Angola(Português) Mozambique(Português)
North America
United States(English) Canada(English) Haiti(Ayiti) Mexico(español)
HomeProductsFiltersPower Line Filter Modules082.00601.00-RS
082.00601.00-RS Image
Image may be representation.
See specifications for product details.
EXPRESS OPTION
Payment method

082.00601.00-RS - Astrodyne TDI

Manufacturer Part Number
082.00601.00-RS
Manufacturer
Astrodyne TDI
Allelco Part Number
98D-082.00601.00-RS
Warranty
1 Year Allelco Warranty - Find out more
Stock Status:
35,620 pcs available, New & Original
Parts Description
FILTERED PWR ENTRY MODULES WITH
Package
Box
Data sheet
082.00601.00-RS.pdf

Datasheets

082(M) Series.pdf
RoHs Status
ROHS3 Compliant
Our certification
In stock: 35620
  • Unit Price: $27.64
  • Subtotal: $0.00

Want a better price?
Add to Cart and Submit RFQ now, we'll contact you immediately.

Quantity Unit Price Ext. Price
1+ $27.64 $27.64
200+ $11.03 $2,206.00
500+ $10.66 $5,330.00
1000+ $10.48 $10,480.00
The above prices does not include taxes and freight rates, which will be calculated on the order pages.

Specifications

082.00601.00-RS Tech Specifications
Astrodyne TDI - 082.00601.00-RS technical specifications, attributes, parameters and parts with similar specifications to Astrodyne TDI - 082.00601.00-RS

Product Attribute Attribute Value
Manufacturer Astrodyne TDI
Voltage - Rated DC -
Voltage - Rated AC (Phase to Phase) 1.45 kV
Voltage - Rated AC 250V
Termination Style IEC Inlet-C14, Quick Connect
Series 82
Package Box
Operating Temperature -25°C ~ 85°C
Mounting Type Chassis Mount
Product Attribute Attribute Value
Inductance -
Frequency - Operating 50/60Hz
Filter Type Single Phase
Current 6 A
Configuration Single Stage
Base Product Number 082
Approval Agency cURus, VDE
Applications General Purpose

Environmental & Export Classifications

ATTRIBUTE DESCRIPTION
RoHs Status ROHS3 Compliant
Moisture Sensitivity Level (MSL) Not Applicable
REACH Status REACH Unaffected
ECCN EAR99
HTSUS 8548.00.0000

Frequently Asked Questions(FAQ)

What is the maximum inrush current the Astrodyne TDI 082.00601.00-RS can safely handle during power-on transients?
The 082.00601.00-RS is rated for continuous operation at 6 A, but inrush current handling depends on the filter's internal component design and the downstream circuit topology. Single-stage EMI filters like the 082.00601.00-RS typically tolerate brief inrush pulses 2–4 times the rated current for millisecond durations without component degradation, provided the source impedance limits peak current. However, sustained inrush above 20 A or repeated high-energy transients may stress the internal capacitors and inductors. For applications with significant inrush (such as resistive heater loads or large transformer primaries), verify the specific inrush profile against the 082.00601.00-RS datasheet derating curves, or consider adding series current-limiting elements upstream.
Can the Astrodyne TDI 082.00601.00-RS be used in three-phase applications, or is it strictly single-phase?
The 082.00601.00-RS is designed for single-phase input only, as stated in its Single Phase filter classification. Attempting to connect it to a three-phase supply (whether line-to-line or across phase conductors) will result in unbalanced voltage stress across the filter's capacitors and inductors, leading to premature failure or inadequate EMI suppression on one or more phases. For three-phase 250 VAC equipment, a separate three-phase line filter must be selected; the 082.00601.00-RS cannot be paralleled or adapted for polyphase duty.
How does the operating temperature range of -25°C to 85°C for the 082.00601.00-RS affect capacitor reliability in high-ambient industrial environments?
The 082.00601.00-RS specifies an operating range of -25°C to 85°C, which is typical for industrial-grade EMI filters with film or electrolytic capacitors. At the upper limit (85°C ambient), the internal capacitors degrade at an accelerated rate; electrolytic capacitors especially lose approximately 10–15% of their effective lifetime for every 10°C rise above 65°C. In applications where the 082.00601.00-RS operates continuously near 85°C—such as equipment mounted in unventilated enclosures or near heat sources—expect a reduced service life compared to cooler installations. Designers should either thermally manage the equipment to keep the 082.00601.00-RS below 70°C, or plan for preventive replacement intervals (typically 5–7 years instead of 10+ years). Lower operating temperatures extend capacitor lifespan and improve long-term filtering stability.
What is the attenuation performance difference between the single-stage 082.00601.00-RS and a multi-stage EMI filter for the same 250 VAC, 6 A application?
The 082.00601.00-RS uses a single-stage topology, typically providing 30–50 dB of attenuation across the 0.15–30 MHz EMC test range, depending on load impedance and frequency. Multi-stage filters (two or three stages) generally achieve 60–80 dB or higher attenuation across the same range by adding additional LC networks, providing superior noise suppression and margin against conducted emissions limits (like EN 55011 Class A or B). However, multi-stage designs incur higher cost, larger physical size, and increased voltage drop. The 082.00601.00-RS single-stage design is appropriate for applications with moderate EMI generation (such as general industrial switching power supplies or motor drives rated ≤3 kW) where Class A or light Class B compliance is achievable. For high-power RF sources or extreme EMI environments, a multi-stage filter or the next size up in Astrodyne's series should be evaluated.
Does the IEC C14 inlet connection on the 082.00601.00-RS support both push-fit and threaded mounting, or only quick-connect?
The 082.00601.00-RS features an IEC Inlet-C14 with Quick Connect termination style, meaning the internal contacts use spring-loaded push-fit connectors designed for mating IEC C13 plugs without threaded coupling. This differs from some industrial filters that employ threaded or screw-locking C14 inlets for enhanced mechanical security. The quick-connect design on the 082.00601.00-RS reduces assembly time and allows tool-free mating but may require positive strain relief (cable clamps or routing guides) in high-vibration environments to prevent intermittent disconnection. If threaded C14 coupling is a requirement for your application, verify connector compatibility before procurement, as the 082.00601.00-RS is not retrofittable to threaded inlets.
How does the 082.00601.00-RS compare to competitor single-stage 250 VAC filters in terms of leakage current and safety certification?
The 082.00601.00-RS carries dual certification (cURus and VDE), which indicates compliance with North American (UL/CSA) and European safety standards. Most single-stage competitors in the 250 VAC, 6 A segment also carry dual certification but may differ in leakage current specification—typically 3.5–5 mA at 250 VAC for Class II double-insulated designs. The 082.00601.00-RS leakage current should be verified against the full datasheet, as single-stage filters often sit at the upper end of acceptable leakage (3–5 mA) due to parasitic capacitance across the common-mode choke and filter capacitors. In medical or Class III applications requiring <1 mA leakage, a medical-grade filter or higher-stage design is necessary. For general industrial use (Class I equipment with earth bonding), the leakage of the 082.00601.00-RS is acceptable and does not typically require additional RCD protection beyond standard facility wiring.
What is the insertion loss (voltage drop) of the 082.00601.00-RS at full rated current, and how does it affect power supply design?
Single-stage EMI filters like the 082.00601.00-RS introduce series inductance (typically 0.5–2 µH) and DC resistance in the common-mode path, resulting in a voltage drop of approximately 0.3–1.0 V at full 6 A load (depending on design). This insertion loss translates to approximately 1.8–6 W of heat dissipation at rated current and must be factored into the 082.00601.00-RS thermal budget and enclosure ventilation. For 250 VAC downstream rectifier or switch-mode power supply circuits, a 0.5–1 V drop is typically acceptable and does not require compensation. However, in marginal mains voltage scenarios (such as 230 VAC sites already operating at the lower limit of a 230 VAC ±10% tolerance band), the 082.00601.00-RS insertion loss may push the downstream rectified voltage below acceptable limits; in such cases, verify that the power supply input capacitor and front-end regulation can handle the reduced DC bus voltage without dropout or excessive ripple.
Is the 082.00601.00-RS suitable for retrofit into existing equipment designed for a different filter connector type?
The 082.00601.00-RS uses an IEC C14 inlet with quick-connect termination, which is the industry standard for general-purpose industrial equipment. If your existing equipment uses a different inlet (such as threaded C14, proprietary connectors, or terminal lugs), the 082.00601.00-RS cannot be directly retrofitted without rewiring or adapter plates. Adapter solutions introduce additional connection points (and thus higher contact resistance and potential failure modes) and may not meet the original equipment's safety certification. Before specifying the 082.00601.00-RS as a replacement, verify that the original filter mounting location, electrical path, and connector type are compatible; if not, evaluate equipment re-certification or select a filter variant that matches the existing mechanical and electrical interface.
How does RoHS3 compliance of the 082.00601.00-RS affect long-term material compatibility and sourcing?
The 082.00601.00-RS is RoHS3 Compliant, indicating the elimination of lead solder, hexavalent chromium, and other restricted substances per EU Directive 2011/65/EU (as amended). RoHS3 compliance simplifies procurement for EU markets and future-proofs the component against tightening regulations; however, lead-free solder and plating finishes on the 082.00601.00-RS exhibit different thermal expansion characteristics and can introduce whisker growth risks if not properly controlled. From a sourcing perspective, RoHS3 certification means the 082.00601.00-RS is widely available through mainstream distributors and is unlikely to face supply restrictions. However, verify that any interconnect materials (cables, connectors, solder joints) used with the 082.00601.00-RS are also RoHS3 compatible to avoid galvanic corrosion or mechanical stress at mixed lead-free/leaded interfaces.
What precautions should be taken when installing the 082.00601.00-RS in environments with high humidity or corrosive atmospheres?
Although the 082.00601.00-RS is rated MSL Not Applicable (indicating it does not absorb significant moisture), the internal capacitors and PCB traces can still degrade in sustained high-humidity (>80% RH) or corrosive environments (saltwater spray, chemical fumes). The 082.00601.00-RS should be installed with adequate enclosure protection—at minimum, an IP54-rated cabinet with silica gel desiccant packs or active climate control. Copper traces on the filter PCB can oxidize or develop conductive paths over time in corrosive atmospheres, potentially shorting high-voltage nodes. For marine, coastal, or chemical-plant applications, specify conformal coating on the 082.00601.00-RS internal circuitry, or select an alternative filter with full potting/encapsulation. Ventilation holes in the enclosure should include hydrophobic membranes to allow pressure equalization without admitting moisture.
Can the 082.00601.00-RS be stacked or paralleled with identical units to increase current rating or filtering effectiveness?
Parallel connection of multiple 082.00601.00-RS units is not recommended and may produce undesirable results. Stacking identical filters in parallel does not reliably increase the current rating to 12 A, 18 A, or higher because unequal impedance distribution and manufacturing tolerances cause current to split unevenly across the units, potentially overloading one filter. Additionally, parallel EMI filters can create resonant peaks in the combined filtering curve due to inductive coupling between the individual common-mode chokes, potentially worsening attenuation in certain frequency bands rather than improving it. If a higher current rating is required, select a single larger filter from Astrodyne's product line rated for the full current demand. If higher attenuation is needed, use a multi-stage filter or add a secondary LC network designed for cascade operation, rather than paralleling identical 082.00601.00-RS units.
What is the typical service life expectancy of the 082.00601.00-RS, and are there field-replaceable wear items?
The 082.00601.00-RS service life depends primarily on the lifespan of its internal electrolytic capacitors, which typically degrade over 5–10 years under continuous operation at nominal voltage and temperature. At lower ambient temperatures (below 65°C) and with moderate voltage stresses, the 082.00601.00-RS may provide 10–15 years of reliable service. The common-mode choke inductor and passive components have much longer lifetimes (effectively indefinite under normal electrical stress). The 082.00601.00-RS does not have user-replaceable wear items; once capacitor degradation reaches a threshold (detected by increased leakage current or reduced filtering attenuation), the entire unit must be replaced. To maximize service life, maintain the 082.00601.00-RS at or below 70°C, avoid sustained overvoltage transients (>300 VAC), and plan for preventive replacement at 7–8 years in critical applications. Periodic insulation resistance and leakage current testing can detect degradation before failure occurs.

Parts with Similar Specifications

The three parts on the right have similar specifications to Astrodyne TDI 082.00601.00-RS

Product Attribute 082.00601.00-RSI 082.00101.00-RS 082.00601.00-LS 082.01001.00-RSI
Part Number 082.00601.00-RSI 082.00101.00-RS 082.00601.00-LS 082.01001.00-RSI
Manufacturer Astrodyne TDI Astrodyne TDI Astrodyne TDI Astrodyne TDI
Voltage - Rated AC (Phase to Phase) - - - -
Frequency - Operating - - - -
Base Product Number - DAC34H84 MAX500 ADS62P42
Mounting Type - Surface Mount Through Hole Surface Mount
Configuration - - - S/H-ADC
Series - - - -
Termination Style - - - -
Current - - - -
Approval Agency - - - -
Voltage - Rated AC - - - -
Package - Tape & Reel (TR) Tube Tape & Reel (TR)
Inductance - - - -
Voltage - Rated DC - - - -
Filter Type - - - -
Operating Temperature - -40°C ~ 85°C 0°C ~ 70°C -40°C ~ 85°C
Applications - - - -

082.00601.00-RS Datasheet PDF

Download 082.00601.00-RS pdf datasheets and Astrodyne TDI documentation for 082.00601.00-RS - Astrodyne TDI.

Datasheets
082(M) Series.pdf

Customer Reviews

Evaluation: 10 Articles

  • ECUb***h
    Sep 22, 2026

    Used for repair of an older automotive ECU. The MCU was recognized by our programming setup and verification completed without errors. The repaired board now starts and communicates normally.

  • RS48***ieldTech
    Sep 16, 2026

    Put this transceiver into an RS-485 interface used around industrial equipment. Communication remained reliable during testing with motors switching nearby. Good result for the replacement board.

  • Logi***b_Chris
    Sep 8, 2026

    Purchased for a Cyclone III development project. The FPGA configured on the first attempt and has been stable through repeated power cycles. No problems with the I/O we are using.

  • Circ***FixerTom
    Sep 2, 2026

    Used this rectifier in a high-current power supply repair. Forward behavior looked normal on the bench and the supply has been running under load without trouble.

  • Retr***UWorks
    Aug 31, 2026

    Needed the exact ST10F269Z2Q6 for servicing an older control unit. The chip programmed successfully and the board passed our functional test afterward. Much easier than redesigning around a newer MCU.

  • Andr***PCBLab
    Aug 28, 2026

    I needed this ADC for an older data acquisition board. Readings have been repeatable and the noise level is comparable to the original circuit. Happy with the purchase.

  • Leat***O'Keefe
    Aug 20, 2026

    one of my hobbies is skydiving. and when i'm skydiving this works great.

  • Ilen***
    Aug 20, 2026

    This product works considerably well. It secretly improves my basketball by a lot.

  • Indu***ialPower
    Aug 17, 2026

    Installed this IGBT module in a power conversion cabinet. Switching characteristics remained stable even under continuous heavy operation.

  • Nikh***ech
    Aug 13, 2026

    Great low-power MCU for portable equipment. Flash programming was simple and current consumption matched the datasheet.

Write a Review

Your Email address will not be published.

Shipment

Delivery Time

In-stock items can be shipped within 24 hours. Some parts will be arranged for delivery within 1-2 days from the date all items arrive at our warehouse. And Allelco ships order once a day at about 17:00, except Sunday. Once the goods are shipped, the estimated delivery time depends on the shipping methods and Delivery destination. The table below shows are the logistic time for some common countries.

Delivery Cost

  1. Use your express account for shipment if you have one.
  2. Use our account for the shipment. Refer to the table below for the approximate charges.
(Different time frame / countries / package size has different price.)

Delivery Method

  1. Global Common Shipment by DHL / UPS / FedEx / TNT / EMS / SF we support.
  2. Others more shipping ways, please get in touch with your customer manager.

Common Countries Logistic Time Reference
Region Country Logistic Time(Day)
America United States 5
Brazil 7
Europe Germany 5
United Kingdom 4
Italy 5
Oceania Australia 6
New Zealand 5
Asia India 4
Japan 4
Middle East Israel 6
DHL & FedEx Shipment Charges Reference
Shipment charges(KG) Reference DHL(USD$)
0.00kg-1.00kg USD$30.00 - USD$60.00
1.00kg-2.00kg USD$40.00 - USD$80.00
2.00kg-3.00kg USD$50.00 - USD$100.00
Note:
The above table is for reference only. There may have some data bias for the uncontrollable factors.
Contact us if you have any questions.
  • QC (Quality Warranty)
  • Payment Support
  • Packaging
  • Certifications & Memberships

QC (Quality Warranty)

Allelco is committed to exceeding customer expectations through customer service excellence, order accuracy, and on-time delivery.
This is achieved through our commitment to the continual improvement of our processes, services, and products.


Strict quality inspection builds a solid foundation for electronic component quality.
  1. Visual inspection
  2. Performance testing and reliability verification
  3. Standardized full-process testing
  4. Precise control of every parameter
We eliminate defective components and ensure the stable operation of electronic devices through professional quality standards.

Payment Support

The payment method can be chosen from the methods shown below: Wire Transfer (T/T, Bank Transfer), Western Union, Credit card, PayPal.
  • HKBea
  • Paypal
  • MasterCard
  • Western-Union
  • VISA
Stable Delivery, Sincere Partnership — Your Faithful Supply Chain Partner
  • Efficient Supply Management
  • Cost-Saving Procurement
  • Fast Sourcing & Delivery
Contact us if you have any questions.

Packaging

Electrostatic Discharge Protection and Handling

All electrostatic-sensitive components are handled in accordance with electrostatic discharge control procedures. The products are hermetically sealed in anti-static safe packaging to prevent electrostatic damage. Appropriate labeling is also applied for identification and traceability. This ensures product integrity during storage, handling and transportation.


ESD

Certifications & Memberships

Third-party certified, strict quality control. Our certification
  • ISO 9001: 2015
  • ISO 13485: 2016
  • ISO 14001: 2015
  • ISO 28000: 2007
  • ISO 45001: 2018
  • GB/T 27922-2011
  • SMTA
  • IPC
  • ESD
  • PSMA
082.00601.00-RS Image

082.00601.00-RS

Astrodyne TDI
98D-082.00601.00-RS

Want a better price? Add to Cart and Submit RFQ now, we'll contact you immediately.

0 RFQ
Shopping cart (0 Items)
It is empty.
Compare List (0 Items)
It is empty.
Feedback

Your feedback matters! At Allelco, we value the user experience and strive to improve it constantly.
Please share your comments with us via our feedback form, and we'll respond promptly.
Thank you for choosing Allelco.

Subject
E-mail
Comments
Captcha
Drag or click to upload file
Upload File
types: .xls, .xlsx, .doc, .docx, .jpg, .png and .pdf.
Max file size: 10MB