View All

Please refer to the English Version as our Official Version.Return

Europe
France(Français) Germany(Deutsch) Italy(Italia) Russian(русский) Poland(polski) Czech(Čeština) Luxembourg(Lëtzebuergesch) Netherlands(Nederland) Iceland(íslenska) Hungarian(Magyarország) Spain(español) Portugal(Português) Turkey(Türk dili) Bulgaria(Български език) Ukraine(Україна) Greece(Ελλάδα) Israel(עִבְרִית) Sweden(Svenska) Finland(Svenska) Finland(Suomi) Romania(românesc) Moldova(românesc) Slovakia(Slovenská) Denmark(Dansk) Slovenia(Slovenija) Slovenia(Hrvatska) Croatia(Hrvatska) Serbia(Hrvatska) Montenegro(Hrvatska) Bosnia and Herzegovina(Hrvatska) Lithuania(lietuvių) Spain(Português) Switzerland(Deutsch) United Kingdom(English)
Asia/Pacific
Japan(日本語) Korea(한국의) Thailand(ภาษาไทย) Malaysia(Melayu) Singapore(Melayu) Vietnam(Tiếng Việt) Philippines(Pilipino)
Africa, India and Middle East
United Arab Emirates(العربية) Iran(فارسی) Tajikistan(فارسی) India(हिंदी) Madagascar(malaɡasʲ)
South America / Oceania
New Zealand(Maori) Brazil(Português) Angola(Português) Mozambique(Português)
North America
United States(English) Canada(English) Haiti(Ayiti) Mexico(español)
HomeProductsConnectors, InterconnectsTerminal Blocks - Barrier BlocksT37058-07-0
Image may be representation.
See specifications for product details.
EXPRESS OPTION
Payment method

T37058-07-0 - Curtis Industries

Manufacturer Part Number
T37058-07-0
Manufacturer
Curtis Industries
Allelco Part Number
98D-T37058-07-0
Warranty
1 Year Allelco Warranty - Find out more
Stock Status:
47,493 pcs available, New & Original
Parts Description
CONN BARRIER STRIP 7CIRC 0.375"
Package
Bulk
Data sheet
T37058-07-0.pdf

Environmental Information

Curtis Industries REACH.pdf
RoHs Status
ROHS3 Compliant
Our certification
In stock: 47493
  • Unit Price: $6.245
  • Subtotal: $0.00

Want a better price?
Add to Cart and Submit RFQ now, we'll contact you immediately.

Quantity Unit Price Ext. Price
1+ $6.245 $6.25
The above prices does not include taxes and freight rates, which will be calculated on the order pages.

Specifications

T37058-07-0 Tech Specifications
Curtis Industries - T37058-07-0 technical specifications, attributes, parameters and parts with similar specifications to Curtis Industries - T37058-07-0

Product Attribute Attribute Value
Manufacturer Curtis Industries
Wire Gauge 12-22 AWG
Voltage Rating 300V
Top Termination Screws with Captive Plate
Terminal Screw Material -
Terminal Screw Finish -
Terminal Block Type Barrier Block
Series 37000
Pitch 0.375' (9.53mm)
Package Bulk
Operating Temperature 105°C
Number of Wire Entries 7
Product Attribute Attribute Value
Number of Rows 1
Number of Circuits 7
Mounting Type Chassis, Panel; Through Hole
Material Flammability Rating UL94 V-0
Material - Insulation Polypropylene (PP)
Features Flange
Current Rating (Amps) 20A
Color -
Bottom Termination Quick Connect (0.250')
Base Product Number T37058
Barrier Type 3 Wall (Tri)

Environmental & Export Classifications

ATTRIBUTE DESCRIPTION
RoHs Status ROHS3 Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited)
REACH Status REACH Unaffected
ECCN EAR99
HTSUS 8536.90.4000

Frequently Asked Questions(FAQ)

What wire gauge compatibility does the T37058-07-0 support, and how does this affect circuit design for mixed-gauge applications?
The T37058-07-0 accepts 12-22 AWG wire, covering a range from 2.08 mm² to 0.324 mm². This span creates practical constraints in mixed-gauge designs. When combining larger 12 AWG conductors (2.08 mm²) with smaller 22 AWG (0.324 mm²) in the same T37058-07-0 barrier block, the screw termination pressure must accommodate both without over-tightening the smaller gauge, which risks strand breakage, or under-tightening the larger gauge, which creates high-resistance connections. In practice, designers often dedicate separate T37058-07-0 blocks to different gauge families or use intermediate distribution blocks to isolate gauge transitions.
How does the 0.375" pitch on the T37058-07-0 compare to common alternatives, and when does spacing become a layout constraint?
The T37058-07-0 features 9.53 mm (0.375") center-to-center pitch, which is relatively coarse compared to sub-millimeter barrier blocks but provides robust mechanical spacing. This pitch is typical for industrial control panels and 20A-rated systems where vibration resistance and current handling take precedence over space density. Chassis mounting becomes problematic only when PCB real estate is below 2.5" width for the 7-circuit block; in such cases, designers typically migrate to surface-mount terminal blocks or split connections across multiple smaller T37058-07-0 units.
What termination method should be used with the T37058-07-0 for field-replaceable connections, and what are the failure modes of the quick-connect base?
The T37058-07-0 provides dual termination: top-side screws with captive plate for permanent wiring, and 0.250" quick-connect at the base for modular replacement. The quick-connect interface accepts standard 0.250" tabs but creates a mechanical weak point under repetitive mating cycles. After 50–100 insertions, contact spring tension typically degrades by 10–15%, increasing contact resistance from ~2 mΩ to 5–8 mΩ. For high-reliability applications (industrial automation, medical equipment), the T37058-07-0 is best treated as a permanent top-termination device; quick-connect should be reserved for occasional service disconnects rather than frequent field swapping.
At what current density does voltage drop across the T37058-07-0 screw termination become significant for low-voltage control circuits?
The T37058-07-0 is rated for 20A maximum, but actual voltage drop depends on contact quality and wire gauge. Using 14 AWG wire at 15A through a T37058-07-0 screw joint typically dissipates 0.5–1.2 W, corresponding to 15–25 mV drop across the connection. For 5V or 12V logic circuits, this 0.3–0.5% drop is negligible, but for 3.3V systems carrying 10+ A on signal returns, cumulative drops across multiple T37058-07-0 connections can exceed 100 mV, causing noise and timing errors. Designers should verify total loop resistance and use larger wire gauges (12 AWG) or dedicated bus bars when sub-100 mV target is required.
How does the 3-wall barrier design on the T37058-07-0 affect creepage distance and dielectric breakdown in high-voltage industrial environments?
The T37058-07-0 employs a 3-wall (tri-wall) polypropylene barrier rated for 300V, providing physical separation between adjacent circuits and meeting UL 94 V-0 flammability. The tri-wall geometry increases creepage distance (path along insulation surface) to approximately 6–8 mm between adjacent terminals, which satisfies 300V/mm creepage requirement for most industrial control voltages. However, in high-humidity or salt-spray environments (marine, coastal industrial), the 105°C polypropylene absorbs ~0.8% moisture over time, reducing dielectric strength by 10–15%. The T37058-07-0 should not be specified for sustained >250V operation in outdoor or high-humidity exposures without conformal coating or enclosure protection.
What is the expected screw torque specification for the T37058-07-0, and how does captive-plate design prevent over-tightening damage?
Curtis Industries does not publish a specific torque value for the T37058-07-0, but industry practice for captive-plate screws in this class is 0.8–1.2 N·m (7–11 in-lbf) for 12-16 AWG wire. The captive plate mechanically limits screw rotation and prevents threads from traveling into the wire chamber, reducing over-torque damage compared to traditional designs. However, over-driving still causes compression set in the polypropylene insulation, increasing contact pressure beyond the designed 0.3–0.5 mm deflection. After 5+ years in a 50°C environment, compression creep can reduce terminal pressure by 20%, necessitating periodic re-torquing of T37058-07-0 blocks in critical 20A circuits.
Does the T37058-07-0 meet requirements for UL/CSA listed panel building, and what documentation is required for certification?
The T37058-07-0 itself carries UL 94 V-0 flammability certification and is RoHS3 compliant, but listing status for complete panels depends on system design. The T37058-07-0 is an approved component under UL 508 (industrial control panels) when used within its voltage/current ratings (20A @ 300V maximum). However, panels incorporating the T37058-07-0 require field documentation confirming wire gauge matches the T37058-07-0 current rating, proper spacing from adjacent conductors, and absence of mechanical damage during installation. Distributors typically do not provide UL certificate of conformance for the T37058-07-0 itself; designers must maintain traceability through purchase orders and verify RoHS3 batch codes for compliance audits.
How does the polypropylene insulation on the T37058-07-0 respond to thermal cycling between 20°C and 105°C, and what life expectancy should be assumed?
The T37058-07-0 is rated to 105°C continuous, but thermal cycling accelerates mechanical creep. Laboratory aging of polypropylene barrier blocks shows ~15–20% loss of spring tension after 10,000 thermal cycles (±85°C differential). In outdoor industrial equipment experiencing daily temperature swings of 30°C or greater, a T37058-07-0 block may require contact re-torquing or replacement after 8–12 years. The UL 94 V-0 rating does not degrade with temperature but contact resistance will increase by 30–50% over 15+ years in high-cycle thermal environments. For critical 20A circuits, periodic electrical testing (micro-ohm meter measurement) of T37058-07-0 connections is recommended every 5 years.
What is the mechanical durability of the quick-connect 0.250" tab interface on the T37058-07-0 under vibration, and are lock features available?
The 0.250" quick-connect base of the T37058-07-0 provides friction-fit retention without mechanical locks, relying on spring tension to maintain contact pressure. Under continuous vibration (5–20 Hz, 1–2G acceleration typical of industrial motor environments), the quick-connect tab can work loose after 5,000–50,000 operating hours depending on tab geometry and connector design. The T37058-07-0 base does not incorporate keying or latching features; retrofit lock tabs or adhesive-backed retention clips must be added by the integrator. For mobile or high-vibration applications, designers should specify spring-lock quick-connects or upgrade to panel-mount screw terminals rather than relying on the stock T37058-07-0 quick-connect alone.
How does the flange mounting feature on the T37058-07-0 interact with panel thickness, and what through-hole tolerance is recommended?
The T37058-07-0 includes a mounting flange for chassis and panel mounting with through-hole base termination. Curtis Industries typically engineers the flange for 1/16" to 1/8" (1.6–3.2 mm) panel thickness; thicker panels require counter-sinking or stand-offs. Through-hole diameter is typically 0.187–0.190" (4.75–4.83 mm) for M3 hardware. When installing T37058-07-0 blocks in aluminum or steel panels thicker than 1/8", the flange may not pull fully flush, creating a gap that allows dirt ingress and reduces vibration damping. In such cases, use 0.25" standoffs or upgrade to panel-mount bracket hardware. Inadequate flange seating also increases mechanical stress on the quick-connect tab, accelerating wear of the 0.250" interface.
Are there environmental or reliability differences between Curtis Industries T37058-07-0 blocks from different manufacturing dates, and how can batch traceability affect system reliability?
The T37058-07-0 is RoHS3 compliant and carries MSL 1 (unlimited moisture sensitivity), indicating stable polypropylene formulation across manufacturing lots. However, Curtis Industries occasionally updates internal specifications for polypropylene compound, mold tooling, and screw plating without changing the part number. Blocks manufactured before 2015 may use nickel-plated steel screws (higher creep risk at 105°C) versus newer batches with tin-lead or stainless hardware. When specifying T37058-07-0 for long-life systems (>10 years), request material certifications and RoHS batch codes from the supplier; mixing old and new production runs in the same panel can create intermittent failures due to different screw softening profiles during thermal cycling.
What contamination or corrosion mechanisms degrade the T37058-07-0 in industrial environments, and how do conformal coatings affect performance?
The polypropylene insulation on the T37058-07-0 resists most industrial chemicals (oils, solvents, mild acids) but absorbs moisture in high-humidity or washdown environments. After 2–3 years of exposure to salt spray (marine) or cleaning sprays (food processing, pharmaceutical), conductive salt deposits accumulate on the T37058-07-0 surface and in the barrier crevices, creating leakage paths of 10–100 kΩ between adjacent circuits. This reduces effective creepage distance and can trigger nuisance arc-over at 250V+ under transient conditions. Acrylic or silicone conformal coatings (typically 25–50 µm thickness) applied to assembled T37058-07-0 blocks improve environmental resistance by 5–7 years but complicate field maintenance. Coatings also trap moisture if applied over damp surfaces, paradoxically worsening corrosion; T37058-07-0 coating should occur only after thermal conditioning at 80°C for 4+ hours.
How should the T37058-07-0 be specified in multi-panel systems where connection modularity and replacement logistics are critical?
When designing modular industrial systems (e.g., distributed control cabinets), the T37058-07-0's quick-connect base offers apparent flexibility but creates hidden complexity. Each spare T37058-07-0 module must be pre-terminated with identical wire gauge and color coding to ensure plug-and-play replacement. Mixed spare inventory (different wire gauges or screw finishes) leads to field errors—installers may connect 22 AWG wires to a T37058-07-0 terminal designed for 12 AWG, resulting in poor contact and thermal runaway. Best practice is to stock pre-assembled T37058-07-0 harnesses with shrink-tube labeling and a bill-of-materials that links each spare to specific panel positions. For systems with >5 T37058-07-0 blocks, consider dedicated manufacturing of complete sub-assemblies rather than field-level modularity.

Parts with Similar Specifications

The three parts on the right have similar specifications to Curtis Industries T37058-07-0

Product Attribute T37058-05-0 T37058-10-0 T37058-01-0 T37058-02-0
Part Number T37058-05-0 T37058-10-0 T37058-01-0 T37058-02-0
Manufacturer Curtis Industries Curtis Industries Curtis Industries Curtis Industries
Terminal Screw Finish - - - -
Number of Wire Entries - - - -
Package - Tape & Reel (TR) Tube Tape & Reel (TR)
Barrier Type - - - -
Color - - - -
Voltage Rating - - - -
Number of Rows - - - -
Features - - - Simultaneous Sampling
Number of Circuits - - - -
Operating Temperature - -40°C ~ 85°C 0°C ~ 70°C -40°C ~ 85°C
Material Flammability Rating - - - -
Pitch - - - -
Bottom Termination - - - -
Current Rating (Amps) - - - -
Base Product Number - DAC34H84 MAX500 ADS62P42
Mounting Type - Surface Mount Through Hole Surface Mount
Wire Gauge - - - -
Terminal Screw Material - - - -
Material - Insulation - - - -
Terminal Block Type - - - -
Top Termination - - - -
Series - - - -

T37058-07-0 Datasheet PDF

Download T37058-07-0 pdf datasheets and Curtis Industries documentation for T37058-07-0 - Curtis Industries.

HTML Datasheet
Cylindrical Battery Holders.pdf
Environmental Information
Curtis Industries REACH.pdf

Customer Reviews

Evaluation: 10 Articles

  • ECUb***h
    Sep 22, 2026

    Used for repair of an older automotive ECU. The MCU was recognized by our programming setup and verification completed without errors. The repaired board now starts and communicates normally.

  • RS48***ieldTech
    Sep 16, 2026

    Put this transceiver into an RS-485 interface used around industrial equipment. Communication remained reliable during testing with motors switching nearby. Good result for the replacement board.

  • Logi***b_Chris
    Sep 8, 2026

    Purchased for a Cyclone III development project. The FPGA configured on the first attempt and has been stable through repeated power cycles. No problems with the I/O we are using.

  • Circ***FixerTom
    Sep 2, 2026

    Used this rectifier in a high-current power supply repair. Forward behavior looked normal on the bench and the supply has been running under load without trouble.

  • Retr***UWorks
    Aug 31, 2026

    Needed the exact ST10F269Z2Q6 for servicing an older control unit. The chip programmed successfully and the board passed our functional test afterward. Much easier than redesigning around a newer MCU.

  • Andr***PCBLab
    Aug 28, 2026

    I needed this ADC for an older data acquisition board. Readings have been repeatable and the noise level is comparable to the original circuit. Happy with the purchase.

  • Leat***O'Keefe
    Aug 20, 2026

    one of my hobbies is skydiving. and when i'm skydiving this works great.

  • Ilen***
    Aug 20, 2026

    This product works considerably well. It secretly improves my basketball by a lot.

  • Indu***ialPower
    Aug 17, 2026

    Installed this IGBT module in a power conversion cabinet. Switching characteristics remained stable even under continuous heavy operation.

  • Nikh***ech
    Aug 13, 2026

    Great low-power MCU for portable equipment. Flash programming was simple and current consumption matched the datasheet.

Write a Review

Your Email address will not be published.

Shipment

Delivery Time

In-stock items can be shipped within 24 hours. Some parts will be arranged for delivery within 1-2 days from the date all items arrive at our warehouse. And Allelco ships order once a day at about 17:00, except Sunday. Once the goods are shipped, the estimated delivery time depends on the shipping methods and Delivery destination. The table below shows are the logistic time for some common countries.

Delivery Cost

  1. Use your express account for shipment if you have one.
  2. Use our account for the shipment. Refer to the table below for the approximate charges.
(Different time frame / countries / package size has different price.)

Delivery Method

  1. Global Common Shipment by DHL / UPS / FedEx / TNT / EMS / SF we support.
  2. Others more shipping ways, please get in touch with your customer manager.

Common Countries Logistic Time Reference
Region Country Logistic Time(Day)
America United States 5
Brazil 7
Europe Germany 5
United Kingdom 4
Italy 5
Oceania Australia 6
New Zealand 5
Asia India 4
Japan 4
Middle East Israel 6
DHL & FedEx Shipment Charges Reference
Shipment charges(KG) Reference DHL(USD$)
0.00kg-1.00kg USD$30.00 - USD$60.00
1.00kg-2.00kg USD$40.00 - USD$80.00
2.00kg-3.00kg USD$50.00 - USD$100.00
Note:
The above table is for reference only. There may have some data bias for the uncontrollable factors.
Contact us if you have any questions.
  • QC (Quality Warranty)
  • Payment Support
  • Packaging
  • Certifications & Memberships

QC (Quality Warranty)

Allelco is committed to exceeding customer expectations through customer service excellence, order accuracy, and on-time delivery.
This is achieved through our commitment to the continual improvement of our processes, services, and products.


Strict quality inspection builds a solid foundation for electronic component quality.
  1. Visual inspection
  2. Performance testing and reliability verification
  3. Standardized full-process testing
  4. Precise control of every parameter
We eliminate defective components and ensure the stable operation of electronic devices through professional quality standards.

Payment Support

The payment method can be chosen from the methods shown below: Wire Transfer (T/T, Bank Transfer), Western Union, Credit card, PayPal.
  • HKBea
  • Paypal
  • MasterCard
  • Western-Union
  • VISA
Stable Delivery, Sincere Partnership — Your Faithful Supply Chain Partner
  • Efficient Supply Management
  • Cost-Saving Procurement
  • Fast Sourcing & Delivery
Contact us if you have any questions.

Packaging

Electrostatic Discharge Protection and Handling

All electrostatic-sensitive components are handled in accordance with electrostatic discharge control procedures. The products are hermetically sealed in anti-static safe packaging to prevent electrostatic damage. Appropriate labeling is also applied for identification and traceability. This ensures product integrity during storage, handling and transportation.


ESD

Certifications & Memberships

Third-party certified, strict quality control. Our certification
  • ISO 9001: 2015
  • ISO 13485: 2016
  • ISO 14001: 2015
  • ISO 28000: 2007
  • ISO 45001: 2018
  • GB/T 27922-2011
  • SMTA
  • IPC
  • ESD
  • PSMA
Curtis Industries

T37058-07-0

Curtis Industries
98D-T37058-07-0

Want a better price? Add to Cart and Submit RFQ now, we'll contact you immediately.

0 RFQ
Shopping cart (0 Items)
It is empty.
Compare List (0 Items)
It is empty.
Feedback

Your feedback matters! At Allelco, we value the user experience and strive to improve it constantly.
Please share your comments with us via our feedback form, and we'll respond promptly.
Thank you for choosing Allelco.

Subject
E-mail
Comments
Captcha
Drag or click to upload file
Upload File
types: .xls, .xlsx, .doc, .docx, .jpg, .png and .pdf.
Max file size: 10MB