View All

Please refer to the English Version as our Official Version.Return

Europe
France(Français) Germany(Deutsch) Italy(Italia) Russian(русский) Poland(polski) Czech(Čeština) Luxembourg(Lëtzebuergesch) Netherlands(Nederland) Iceland(íslenska) Hungarian(Magyarország) Spain(español) Portugal(Português) Turkey(Türk dili) Bulgaria(Български език) Ukraine(Україна) Greece(Ελλάδα) Israel(עִבְרִית) Sweden(Svenska) Finland(Svenska) Finland(Suomi) Romania(românesc) Moldova(românesc) Slovakia(Slovenská) Denmark(Dansk) Slovenia(Slovenija) Slovenia(Hrvatska) Croatia(Hrvatska) Serbia(Hrvatska) Montenegro(Hrvatska) Bosnia and Herzegovina(Hrvatska) Lithuania(lietuvių) Spain(Português) Switzerland(Deutsch) United Kingdom(English)
Asia/Pacific
Japan(日本語) Korea(한국의) Thailand(ภาษาไทย) Malaysia(Melayu) Singapore(Melayu) Vietnam(Tiếng Việt) Philippines(Pilipino)
Africa, India and Middle East
United Arab Emirates(العربية) Iran(فارسی) Tajikistan(فارسی) India(हिंदी) Madagascar(malaɡasʲ)
South America / Oceania
New Zealand(Maori) Brazil(Português) Angola(Português) Mozambique(Português)
North America
United States(English) Canada(English) Haiti(Ayiti) Mexico(español)
HomeProductsConnectors, InterconnectsTerminal Blocks - Barrier BlocksT37058-15-0
Image may be representation.
See specifications for product details.
EXPRESS OPTION
Payment method

T37058-15-0 - Curtis Industries

Manufacturer Part Number
T37058-15-0
Manufacturer
Curtis Industries
Allelco Part Number
98D-T37058-15-0
Warranty
1 Year Allelco Warranty - Find out more
Stock Status:
46,279 pcs available, New & Original
Parts Description
CONN BARRIER STRP 15CIRC 0.375"
Package
Bulk
Data sheet
T37058-15-0.pdf

Environmental Information

Curtis Industries REACH.pdf
RoHs Status
ROHS3 Compliant
Our certification
In stock: 46279
  • Unit Price: $11.399
  • Subtotal: $0.00

Want a better price?
Add to Cart and Submit RFQ now, we'll contact you immediately.

Quantity Unit Price Ext. Price
1+ $11.399 $11.40
The above prices does not include taxes and freight rates, which will be calculated on the order pages.

Specifications

T37058-15-0 Tech Specifications
Curtis Industries - T37058-15-0 technical specifications, attributes, parameters and parts with similar specifications to Curtis Industries - T37058-15-0

Product Attribute Attribute Value
Manufacturer Curtis Industries
Wire Gauge 12-22 AWG
Voltage Rating 300V
Top Termination Screws with Captive Plate
Terminal Screw Material -
Terminal Screw Finish -
Terminal Block Type Barrier Block
Series 37000
Pitch 0.375' (9.53mm)
Package Bulk
Operating Temperature 105°C
Number of Wire Entries 15
Product Attribute Attribute Value
Number of Rows 1
Number of Circuits 15
Mounting Type Chassis, Panel; Through Hole
Material Flammability Rating UL94 V-0
Material - Insulation Polypropylene (PP)
Features Flange
Current Rating (Amps) 20A
Color -
Bottom Termination Quick Connect (0.250')
Base Product Number T37058
Barrier Type 3 Wall (Tri)

Environmental & Export Classifications

ATTRIBUTE DESCRIPTION
RoHs Status ROHS3 Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited)
REACH Status REACH Unaffected
ECCN EAR99
HTSUS 8536.90.4000

Frequently Asked Questions(FAQ)

What wire gauges can I safely terminate in the T37058-15-0 barrier block connector?
The T37058-15-0 accepts 12–22 AWG wire at all 15 circuits. The 20A current rating supports this gauge range without derating across the operating temperature to 105°C. For 20A circuits, 12 AWG copper wire is preferred to minimize voltage drop over typical interconnect runs; 14 AWG remains acceptable for the same current but introduces approximately 25% additional resistance per unit length. The captive plate design on the T37058-15-0 secures the wire and prevents partial withdrawal during thermal cycling, which is critical when operating near the 105°C upper limit. Always verify your wire insulation temperature rating meets or exceeds 105°C to ensure the termination remains reliable throughout the thermal envelope.
How does the 0.375" pitch on the T37058-15-0 affect PCB layout and panel space allocation?
The T37058-15-0 pitch of 0.375" (9.53mm) per circuit yields a total block footprint of approximately 5.625" across all 15 circuits in a single row. This spacing is typical for industrial control and power distribution panels where operator access and maintenance require clearance between adjacent connectors. The single-row configuration of the T37058-15-0 simplifies wiring diagrams and reduces cross-talk compared to multi-row alternatives; however, the 0.375" spacing may be tighter than legacy 0.500" systems, requiring verification of your panel cutout template and wire management routing. The flange-mounted design of the T37058-15-0 permits surface mounting on vertical panels without requiring additional brackets, reducing assembly labor.
Why is the 300V rating on the T37058-15-0 sufficient or insufficient for my three-phase industrial control application?
The T37058-15-0 300V rating is suitable for control circuits and single-phase loads up to ~240V RMS with adequate safety margin. For three-phase 480V systems, the T37058-15-0 is not rated for direct main-line termination and cannot be used as a primary distribution block. However, the T37058-15-0 remains applicable for low-voltage control signaling, auxiliary contacts, and sensor circuits derived from a 480V-to-24V transformer. Verify your application's actual line voltage and peak transient conditions; if your circuit includes inductive switching (contactor coils, relay solenoids), transient over-voltage can briefly exceed steady-state ratings, and the T37058-15-0 may require coordination with surge suppression or snubber networks to prevent arc-over across the 3-wall barrier structure.
What is the difference between the quick-connect bottom termination and the screw-terminal top on the T37058-15-0?
The T37058-15-0 features a dual-termination design: the top employs screws with a captive plate for field wiring termination, while the bottom uses quick-connect receptacles (0.250" tabs) for mating to external harnesses or backplane connectors. This asymmetry allows the T37058-15-0 to function as a transition block in modular systems: incoming field wires terminate topside via the captive screw mechanism, and outbound connections route through the quick-connect interface to reduce assembly time. The quick-connect design on the T37058-15-0 enables rapid block replacement without breaking field wiring, improving maintenance efficiency. Ensure your mating connectors are rated for the same 20A current and 300V environment; loose or corroded quick-connect contacts are a common failure mode and can introduce intermittent open circuits.
How does the tri-wall (3-wall) barrier structure on the T37058-15-0 protect against arc tracking and insulation degradation?
The T37058-15-0 incorporates a 3-wall barrier design that isolates each of the 15 circuits into individual compartments, physically separating conductors and reducing the path for arc propagation across adjacent circuits. The polypropylene (PP) insulation material combined with the UL94 V-0 flammability rating indicates the T37058-15-0 will self-extinguish and limit flame spread even under fault conditions. In humid or contaminated environments, the tri-wall structure of the T37058-15-0 increases creepage and clearance distances, reducing the risk of tracking—a progressive carbonization path that bridges insulation over time. The 3-wall barrier does not eliminate arc risk entirely; at 300V under high-current transients or inadequate wire crimping, arcing can still occur within a single circuit. The barrier's primary function in the T37058-15-0 is containment: preventing a fault in one circuit from cascading to neighbors, which is critical in safety-related control systems.
Is the T37058-15-0 suitable for outdoor or wet-environment installations without additional environmental protection?
The T37058-15-0 is not inherently sealed or potted and will not withstand prolonged direct moisture exposure without a secondary enclosure. The polypropylene (PP) housing of the T37058-15-0 is moisture-resistant but not waterproof; ingress of water or condensation into the quick-connect receptacles can lead to corrosion and intermittent contact resistance. For outdoor or high-humidity industrial settings, the T37058-15-0 must be mounted within a NEMA 4X (stainless steel) or equivalent rated enclosure. The captive-plate screw terminals on the T37058-15-0 provide some protection against accidental contact once tightened, but the open top design leaves the connection points accessible to dust and moisture. RoHS3 compliance of the T37058-15-0 does not confer environmental sealing; REACH Unaffected status confirms material compliance but does not address humidity or salt-spray resistance.
Why does the T37058-15-0 specify 12–22 AWG but perform differently at the extremes of that range under sustained 20A loading?
The T37058-15-0 rated current of 20A represents the maximum the connector assembly can withstand thermally; however, 22 AWG copper wire at 20A produces approximately 1.6 watts per 100 feet of conductor length due to I²R losses. If your T37058-15-0 installation includes long cable runs (e.g., >50 feet) at 20A using 22 AWG, the combination of conductor heating and ambient temperature near 105°C can push the actual wire insulation close to its thermal limit, reducing lifespan and increasing failure risk. Conversely, 12 AWG at 20A produces only ~0.2 watts per 100 feet and allows greater thermal margin. For continuous duty on the T37058-15-0, use 12 or 14 AWG when run length exceeds 25 feet; reserve 16–22 AWG for short interconnects or lower current branches (under 10A). The T37058-15-0 screw termination design does not derate based on wire gauge, so the burden of thermal management falls on the design engineer.
Can the T37058-15-0 be used in parallel with other barrier blocks to increase circuit count, and what precautions are necessary?
Multiple T37058-15-0 units can be mechanically mounted side-by-side on a single panel to create a multi-block assembly; however, each T37058-15-0 remains electrically independent. There is no electrical connection between blocks unless the user explicitly wires a common return or ground point. When configuring multiple T37058-15-0 blocks, verify that all incoming power and signal sources share a unified ground reference to prevent ground loops and transient voltage differentials. The 0.375" pitch of individual T37058-15-0 blocks does not inherently provide any cross-block shielding or EMI isolation; if high-speed switching or analog signals are routed through adjacent T37058-15-0 blocks, crosstalk may occur without proper grounding discipline. Document the electrical topology clearly on schematics; a clustered arrangement of multiple T37058-15-0 units is mechanically convenient but electrically requires the same rigor as any parallel connectivity design.
What maintenance or inspection routine is recommended for T37058-15-0 installations operating continuously at or near the 105°C limit?
The T37058-15-0 rated to 105°C does not have a formal maintenance schedule in the datasheet, but field experience in industrial environments suggests periodic inspection at 12–24 month intervals for systems operating continuously near maximum temperature. Visual inspection of the T37058-15-0 should focus on discoloration or embrittlement of the polypropylene housing (yellowing or cracking indicates thermal stress), and physical tightness of all captive-plate screws, as thermal cycling causes micro-relaxation. Check quick-connect receptacles on the T37058-15-0 for oxidation or loose contacts; a light tug on each mated connector should reveal any intermittent fitment. Infrared thermography of a live T37058-15-0 block under full-load conditions can reveal hot-spots indicating internal contact degradation. The UL94 V-0 rating of the T37058-15-0 does not require routine dielectric testing, but if the system experiences electrical surges or lightning events, consider time-domain reflectometry (TDR) to verify conductor continuity within the T37058-15-0.
How do the screw-terminal tolerances and captive-plate design of the T37058-15-0 affect repeatability and rework cycles?
The T37058-15-0 captive-plate screw mechanism is designed for single-pass assembly: the captive plate physically restrains the screw within the block even when fully backed out, preventing loss and ensuring repeatable seating depth across multiple terminations. This design reduces assembly training and minimizes field errors caused by over-torque or under-torque. However, the T37058-15-0 does not specify torque targets in the datasheet; empirical values from Curtis Industries typically range 8–12 in-lb for proper clamping force without stripping the polypropylene threads. Rework of a T37058-15-0 connection requires partial screw removal and re-insertion; repeated cycles (>5 insertions per circuit) can gradually enlarge the polypropylene threads and reduce clamping force. For high-rework applications (e.g., prototype or commissioning environments), consider pre-planning component layout to minimize terminal changes, or budget for T37058-15-0 replacement blocks if extensive field modifications are anticipated.
What are the long-term reliability implications of mixing conductor materials (copper vs. aluminum) in a single T37058-15-0 block?
The T37058-15-0 connector is engineered for copper-to-copper termination via the screw terminals and quick-connect contacts. Terminating aluminum conductors directly to the T37058-15-0 introduces galvanic corrosion risk at the interface; aluminum oxidizes rapidly to an insulating aluminum oxide layer, increasing contact resistance and heat generation under load. If your design requires aluminum conductors (for weight or cost reasons), use a copper crimp adapter at the T37058-15-0 termination point, ensuring the junction is rated for the full 20A circuit. Mixing copper and aluminum within the same T37058-15-0 block is technically possible but creates a two-tier reliability profile: copper circuits remain stable, while aluminum circuits degrade over months to years depending on environmental humidity. Document any aluminum-to-copper transitions in your system schematic and schedule inspection intervals for those specific T37058-15-0 circuits. RoHS3 compliance of the T37058-15-0 does not restrict aluminum use but places responsibility for material compatibility on the system integrator.
How does the single-row configuration of the T37058-15-0 compare to multi-row terminal blocks in terms of electrical performance and design trade-offs?
The T37058-15-0 single-row, 15-circuit layout maximizes operator accessibility and simplifies wire routing compared to stacked multi-row designs (such as two rows of 8 circuits each). The reduced circuit density of the T37058-15-0 increases clearance between adjacent terminals, lowering arc-over risk in high-voltage transient scenarios. However, a single-row T37058-15-0 occupies significantly more horizontal panel space (~5.625" width) than a 2×8 multi-row block (~1.9" width); in space-constrained enclosures, multiple smaller T37058-15-0 units may prove impractical. From an electrical standpoint, the linear arrangement of the T37058-15-0 is preferable for applications where signal integrity is critical (control circuits, instrumentation); the uniform physical separation reduces capacitive coupling and crosstalk compared to tightly nested multi-row designs. The flange-mounting footprint of the T37058-15-0 is not standardized across multi-row competitors, so migration from T37058-15-0 to a higher-density alternative requires mechanical redesign and potential re-qualification.
What is the difference in contact resistance performance between the captive-screw termination and the quick-connect receptacles on the T37058-15-0, and how does this affect circuit voltage drop calculations?
The T37058-15-0 screw termination typically exhibits contact resistance in the 1–3 mΩ range when properly torqued, while the quick-connect receptacles (0.250" tabs) present approximately 2–5 mΩ under nominal insertion force. For a single T37058-15-0 circuit carrying 20A, the cumulative voltage drop across both termination interfaces (screw + quick-connect) may reach ~0.1–0.16V under worst-case combined resistance. In 24V or 48V signal and control circuits, this drop is negligible; in higher-voltage systems (240V, 300V rated), the proportional loss remains <0.1% and is typically masked by supply regulation. However, in precision current-sensing circuits or applications where circuit continuity diagnostics rely on voltage-drop thresholds, the T37058-15-0 contact resistance must be accounted for in the measurement algorithm. If the T37058-15-0 terminations become corroded or partially inserted, contact resistance can spike to 10+ mΩ, introducing unacceptable voltage drop and potential thermal runaway. Specify connector insertion and extraction force limits when procuring mating harnesses to ensure repeatable contact pressure on the T37058-15-0.

Parts with Similar Specifications

The three parts on the right have similar specifications to Curtis Industries T37058-15-0

Product Attribute T37058-19-0 T37058-14-0 T37058-10-0 T37058-11-0
Part Number T37058-19-0 T37058-14-0 T37058-10-0 T37058-11-0
Manufacturer Curtis Industries Curtis Industries Curtis Industries Curtis Industries
Top Termination - - - -
Pitch - - - -
Current Rating (Amps) - - - -
Terminal Screw Finish - - - -
Number of Rows - - - -
Features - - - Simultaneous Sampling
Number of Wire Entries - - - -
Series - - - -
Number of Circuits - - - -
Mounting Type - Surface Mount Through Hole Surface Mount
Bottom Termination - - - -
Material Flammability Rating - - - -
Terminal Screw Material - - - -
Color - - - -
Wire Gauge - - - -
Terminal Block Type - - - -
Barrier Type - - - -
Base Product Number - DAC34H84 MAX500 ADS62P42
Operating Temperature - -40°C ~ 85°C 0°C ~ 70°C -40°C ~ 85°C
Package - Tape & Reel (TR) Tube Tape & Reel (TR)
Material - Insulation - - - -
Voltage Rating - - - -

T37058-15-0 Datasheet PDF

Download T37058-15-0 pdf datasheets and Curtis Industries documentation for T37058-15-0 - Curtis Industries.

HTML Datasheet
Cylindrical Battery Holders.pdf
Environmental Information
Curtis Industries REACH.pdf

Customer Reviews

Evaluation: 10 Articles

  • ECUb***h
    Sep 22, 2026

    Used for repair of an older automotive ECU. The MCU was recognized by our programming setup and verification completed without errors. The repaired board now starts and communicates normally.

  • RS48***ieldTech
    Sep 16, 2026

    Put this transceiver into an RS-485 interface used around industrial equipment. Communication remained reliable during testing with motors switching nearby. Good result for the replacement board.

  • Logi***b_Chris
    Sep 8, 2026

    Purchased for a Cyclone III development project. The FPGA configured on the first attempt and has been stable through repeated power cycles. No problems with the I/O we are using.

  • Circ***FixerTom
    Sep 2, 2026

    Used this rectifier in a high-current power supply repair. Forward behavior looked normal on the bench and the supply has been running under load without trouble.

  • Retr***UWorks
    Aug 31, 2026

    Needed the exact ST10F269Z2Q6 for servicing an older control unit. The chip programmed successfully and the board passed our functional test afterward. Much easier than redesigning around a newer MCU.

  • Andr***PCBLab
    Aug 28, 2026

    I needed this ADC for an older data acquisition board. Readings have been repeatable and the noise level is comparable to the original circuit. Happy with the purchase.

  • Leat***O'Keefe
    Aug 20, 2026

    one of my hobbies is skydiving. and when i'm skydiving this works great.

  • Ilen***
    Aug 20, 2026

    This product works considerably well. It secretly improves my basketball by a lot.

  • Indu***ialPower
    Aug 17, 2026

    Installed this IGBT module in a power conversion cabinet. Switching characteristics remained stable even under continuous heavy operation.

  • Nikh***ech
    Aug 13, 2026

    Great low-power MCU for portable equipment. Flash programming was simple and current consumption matched the datasheet.

Write a Review

Your Email address will not be published.

Shipment

Delivery Time

In-stock items can be shipped within 24 hours. Some parts will be arranged for delivery within 1-2 days from the date all items arrive at our warehouse. And Allelco ships order once a day at about 17:00, except Sunday. Once the goods are shipped, the estimated delivery time depends on the shipping methods and Delivery destination. The table below shows are the logistic time for some common countries.

Delivery Cost

  1. Use your express account for shipment if you have one.
  2. Use our account for the shipment. Refer to the table below for the approximate charges.
(Different time frame / countries / package size has different price.)

Delivery Method

  1. Global Common Shipment by DHL / UPS / FedEx / TNT / EMS / SF we support.
  2. Others more shipping ways, please get in touch with your customer manager.

Common Countries Logistic Time Reference
Region Country Logistic Time(Day)
America United States 5
Brazil 7
Europe Germany 5
United Kingdom 4
Italy 5
Oceania Australia 6
New Zealand 5
Asia India 4
Japan 4
Middle East Israel 6
DHL & FedEx Shipment Charges Reference
Shipment charges(KG) Reference DHL(USD$)
0.00kg-1.00kg USD$30.00 - USD$60.00
1.00kg-2.00kg USD$40.00 - USD$80.00
2.00kg-3.00kg USD$50.00 - USD$100.00
Note:
The above table is for reference only. There may have some data bias for the uncontrollable factors.
Contact us if you have any questions.
  • QC (Quality Warranty)
  • Payment Support
  • Packaging
  • Certifications & Memberships

QC (Quality Warranty)

Allelco is committed to exceeding customer expectations through customer service excellence, order accuracy, and on-time delivery.
This is achieved through our commitment to the continual improvement of our processes, services, and products.


Strict quality inspection builds a solid foundation for electronic component quality.
  1. Visual inspection
  2. Performance testing and reliability verification
  3. Standardized full-process testing
  4. Precise control of every parameter
We eliminate defective components and ensure the stable operation of electronic devices through professional quality standards.

Payment Support

The payment method can be chosen from the methods shown below: Wire Transfer (T/T, Bank Transfer), Western Union, Credit card, PayPal.
  • HKBea
  • Paypal
  • MasterCard
  • Western-Union
  • VISA
Stable Delivery, Sincere Partnership — Your Faithful Supply Chain Partner
  • Efficient Supply Management
  • Cost-Saving Procurement
  • Fast Sourcing & Delivery
Contact us if you have any questions.

Packaging

Electrostatic Discharge Protection and Handling

All electrostatic-sensitive components are handled in accordance with electrostatic discharge control procedures. The products are hermetically sealed in anti-static safe packaging to prevent electrostatic damage. Appropriate labeling is also applied for identification and traceability. This ensures product integrity during storage, handling and transportation.


ESD

Certifications & Memberships

Third-party certified, strict quality control. Our certification
  • ISO 9001: 2015
  • ISO 13485: 2016
  • ISO 14001: 2015
  • ISO 28000: 2007
  • ISO 45001: 2018
  • GB/T 27922-2011
  • SMTA
  • IPC
  • ESD
  • PSMA
Curtis Industries

T37058-15-0

Curtis Industries
98D-T37058-15-0

Want a better price? Add to Cart and Submit RFQ now, we'll contact you immediately.

0 RFQ
Shopping cart (0 Items)
It is empty.
Compare List (0 Items)
It is empty.
Feedback

Your feedback matters! At Allelco, we value the user experience and strive to improve it constantly.
Please share your comments with us via our feedback form, and we'll respond promptly.
Thank you for choosing Allelco.

Subject
E-mail
Comments
Captcha
Drag or click to upload file
Upload File
types: .xls, .xlsx, .doc, .docx, .jpg, .png and .pdf.
Max file size: 10MB