View All

Please refer to the English Version as our Official Version.Return

Europe
France(Français) Germany(Deutsch) Italy(Italia) Russian(русский) Poland(polski) Czech(Čeština) Luxembourg(Lëtzebuergesch) Netherlands(Nederland) Iceland(íslenska) Hungarian(Magyarország) Spain(español) Portugal(Português) Turkey(Türk dili) Bulgaria(Български език) Ukraine(Україна) Greece(Ελλάδα) Israel(עִבְרִית) Sweden(Svenska) Finland(Svenska) Finland(Suomi) Romania(românesc) Moldova(românesc) Slovakia(Slovenská) Denmark(Dansk) Slovenia(Slovenija) Slovenia(Hrvatska) Croatia(Hrvatska) Serbia(Hrvatska) Montenegro(Hrvatska) Bosnia and Herzegovina(Hrvatska) Lithuania(lietuvių) Spain(Português) Switzerland(Deutsch) United Kingdom(English)
Asia/Pacific
Japan(日本語) Korea(한국의) Thailand(ภาษาไทย) Malaysia(Melayu) Singapore(Melayu) Vietnam(Tiếng Việt) Philippines(Pilipino)
Africa, India and Middle East
United Arab Emirates(العربية) Iran(فارسی) Tajikistan(فارسی) India(हिंदी) Madagascar(malaɡasʲ)
South America / Oceania
New Zealand(Maori) Brazil(Português) Angola(Português) Mozambique(Português)
North America
United States(English) Canada(English) Haiti(Ayiti) Mexico(español)
HomeProductsSensors, TransducersPressure Sensors, TransducersLER00750TAMNKAAA15
Image may be representation.
See specifications for product details.
EXPRESS OPTION
Payment method

LER00750TAMNKAAA15 - Honeywell Sensing and Productivity Solutions

Manufacturer Part Number
LER00750TAMNKAAA15
Manufacturer
Honeywell Sensing and Productivity Solutions
Allelco Part Number
98D-LER00750TAMNKAAA15
Warranty
1 Year Allelco Warranty - Find out more
Stock Status:
4,190 pcs available, New & Original
Parts Description
SENSOR 75PSIG SPST-NC 1/4"NPT
Package
Cylinder, Threaded
Data sheet
-
RoHs Status
RoHS Compliant
Our certification
In stock: 4190

Required fields are indicated by an asterisk (*)
Please send RFQ, we will respond immediately.

Quantity

Specifications

LER00750TAMNKAAA15 Tech Specifications
Honeywell Sensing and Productivity Solutions - LER00750TAMNKAAA15 technical specifications, attributes, parameters and parts with similar specifications to Honeywell Sensing and Productivity Solutions - LER00750TAMNKAAA15

Product Attribute Attribute Value
Manufacturer Honeywell Sensing and Productivity Solutions
Voltage - Supply 28V
Termination Style Quick Connect - 0.250" (6.3mm)
Supplier Device Package -
Series LE
Pressure Type Gauge
Port Style Threaded
Port Size Male - 1/4" (6.35mm) NPT
Package / Case Cylinder, Threaded
Product Attribute Attribute Value
Package Bulk
Output Type SPST-NC
Output -
Operating Temperature -40°C ~ 120°C
Operating Pressure 75PSI (517.11kPa)
Maximum Pressure 500PSI (3447.38kPa)
Features -
Base Product Number LER00750
Accuracy -

Environmental & Export Classifications

ATTRIBUTE DESCRIPTION
RoHs Status RoHS Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited)
ECCN EAR99
HTSUS 9026.20.4000

Frequently Asked Questions(FAQ)

What are the key performance specifications of the LER00750TAMNKAAA15 pressure sensor when used in a 75 PSIG industrial monitoring application?
The LER00750TAMNKAAA15 is designed for accurate gauge pressure measurement up to 75 PSI (517.11 kPa), with a maximum rated pressure of 500 PSI (3447.38 kPa) to allow for transient overpressure conditions. It features an SPST-Normally Closed (NC) switch output, making it suitable for fail-safe monitoring systems. With a supply voltage range of 28V and a quick-connect termination style, it integrates efficiently into existing control panels without requiring soldering. Its operating temperature span from -40°C to 120°C ensures reliability in harsh environments common in industrial automation and HVAC systems.
How does the LER00750TAMNKAAA15 compare to other Honeywell LE series pressure sensors in terms of port configuration and mechanical compatibility?
Compared to other models in the LE series such as the LER00500TAMNKAAA15 or LER01000TAMNKAAA15, the LER00750TAMNKAAA15 maintains consistent mechanical and electrical characteristics including the same 1/4" NPT male threaded port and quick-connect termination. However, it is differentiated by its specific 75 PSI nominal rating and corresponding pressure range. This consistency enables designers to standardize on a single housing and mounting interface across multiple pressure thresholds while maintaining interchangeability in systems where space and connector layout are constrained.
In what type of system would the SPST-NC output configuration of the LER00750TAMNKAAA15 be most advantageous?
The Normally Closed (NC) state of the LER00750TAMNKAAA15’s output makes it ideal for safety-critical or alarm-based applications where system integrity must be maintained under normal operation. For example, in compressed air monitoring systems, if the pressure drops below the 75 PSI threshold, the contact opens, triggering an alert or shutdown sequence. This behavior aligns with fail-safe design principles, ensuring immediate response in case of sensor failure or signal loss due to wiring issues.
What design considerations should engineers evaluate when integrating the LER00750TAMNKAAA15 into a high-cycle pressure monitoring application?
Engineers must account for the sensor’s mechanical durability and switching frequency capability. While the device supports pressures up to 500 PSI, frequent cycling near the upper limit may accelerate wear on internal diaphragms or contacts. For high-cycle applications, it is advisable to operate within 60–80% of the maximum pressure to extend service life. Additionally, vibration resistance should be evaluated, especially in mobile or automotive environments, where mounting stability and strain relief for the quick-connect terminals are essential to prevent fatigue-related failures.
Can the LER00750TAMNKAAA15 be used safely in environments with rapid pressure transients or pulsating flows?
The LER00750TAMNKAAA15 is rated for static pressure measurement and is not optimized for dynamic or rapidly changing pressures. In applications involving significant transients—such as pump discharge lines or reciprocating compressors—the mechanical response time and contact bounce characteristics may lead to inaccurate readings or premature contact wear. For such scenarios, a dedicated pressure transducer with analog output and higher bandwidth is recommended instead of relying solely on this switch-type device.
What are the implications of the RoHS compliance and MSL 1 status for the LER00750TAMNKAAA15 in global manufacturing and field replacement scenarios?
RoHS compliance ensures that the LER00750TAMNKAAA15 meets international standards for hazardous substance restrictions, facilitating use in consumer, medical, and regulated industrial equipment without legal or market access barriers. The Moisture Sensitivity Level 1 (MSL 1) designation indicates unlimited floor life under normal storage conditions, simplifying inventory management and reducing the need for baking prior to assembly. This makes the component suitable for just-in-time production and long-term stocking in repair or aftermarket applications.
How does the operating temperature range of the LER00750TAMNKAAA15 influence its suitability for outdoor or extreme environment installations?
With an extended operating temperature range from -40°C to 120°C, the LER00750TAMNKAAA15 can be deployed in demanding environments such as engine compartments, refrigeration systems, or outdoor pneumatic controls without derating. However, thermal expansion of materials at temperature extremes may affect thread engagement and sealing integrity over time. Engineers should ensure proper torque during installation and consider using thread sealants compatible with the full temperature range to maintain leak-free connections.
What precautions should be taken when selecting between the LER00750TAMNKAAA15 and an equivalent analog pressure switch with variable setpoint adjustment?
While the LER00750TAMNKAAA15 offers fixed setpoint accuracy and simplified wiring, an adjustable analog switch allows fine-tuning of the trip point to accommodate system tolerances or calibration drift. If process conditions vary significantly or require precise hysteresis control, the analog alternative may offer better long-term performance. However, the LER00750TAMNKAAA15 provides superior noise immunity and faster switching response due to its solid-state contact design, making it preferable in electrically noisy environments like industrial presses or robotics.

Parts with Similar Specifications

The three parts on the right have similar specifications to Honeywell Sensing and Productivity Solutions LER00750TAMNKAAA15

Product Attribute LER00750TAMNKAAA01 LER00750TBPBKAAA15 LER00750PMYNKCAA15 LER00750TBMBKBAA15
Part Number LER00750TAMNKAAA01 LER00750TBPBKAAA15 LER00750PMYNKCAA15 LER00750TBMBKBAA15
Manufacturer Honeywell Sensing and Productivity Solutions Honeywell Sensing and Productivity Solutions Honeywell Sensing and Productivity Solutions Honeywell Sensing and Productivity Solutions
Supplier Device Package - 196-NFBGA (12x12) 16-PDIP 64-VQFN (9x9)
Accuracy - - - -
Package - Tape & Reel (TR) Tube Tape & Reel (TR)
Base Product Number - DAC34H84 MAX500 ADS62P42
Pressure Type - - - -
Operating Pressure - - - -
Port Style - - - -
Maximum Pressure - - - -
Output Type - Current - Unbuffered Voltage - Buffered -
Package / Case - 196-LFBGA 16-DIP (0.300', 7.62mm) 64-VFQFN Exposed Pad
Series - - - -
Operating Temperature - -40°C ~ 85°C 0°C ~ 70°C -40°C ~ 85°C
Output - - - -
Voltage - Supply - - - -
Termination Style - - - -
Features - - - Simultaneous Sampling
Port Size - - - -

Customers Also Interested in

Recommended Products

Customer Reviews

Evaluation: 10 Articles

  • ECUb***h
    Sep 22, 2026

    Used for repair of an older automotive ECU. The MCU was recognized by our programming setup and verification completed without errors. The repaired board now starts and communicates normally.

  • RS48***ieldTech
    Sep 16, 2026

    Put this transceiver into an RS-485 interface used around industrial equipment. Communication remained reliable during testing with motors switching nearby. Good result for the replacement board.

  • Logi***b_Chris
    Sep 8, 2026

    Purchased for a Cyclone III development project. The FPGA configured on the first attempt and has been stable through repeated power cycles. No problems with the I/O we are using.

  • Circ***FixerTom
    Sep 2, 2026

    Used this rectifier in a high-current power supply repair. Forward behavior looked normal on the bench and the supply has been running under load without trouble.

  • Retr***UWorks
    Aug 31, 2026

    Needed the exact ST10F269Z2Q6 for servicing an older control unit. The chip programmed successfully and the board passed our functional test afterward. Much easier than redesigning around a newer MCU.

  • Andr***PCBLab
    Aug 28, 2026

    I needed this ADC for an older data acquisition board. Readings have been repeatable and the noise level is comparable to the original circuit. Happy with the purchase.

  • Leat***O'Keefe
    Aug 20, 2026

    one of my hobbies is skydiving. and when i'm skydiving this works great.

  • Ilen***
    Aug 20, 2026

    This product works considerably well. It secretly improves my basketball by a lot.

  • Indu***ialPower
    Aug 17, 2026

    Installed this IGBT module in a power conversion cabinet. Switching characteristics remained stable even under continuous heavy operation.

  • Nikh***ech
    Aug 13, 2026

    Great low-power MCU for portable equipment. Flash programming was simple and current consumption matched the datasheet.

Write a Review

Your Email address will not be published.

Shipment

Delivery Time

In-stock items can be shipped within 24 hours. Some parts will be arranged for delivery within 1-2 days from the date all items arrive at our warehouse. And Allelco ships order once a day at about 17:00, except Sunday. Once the goods are shipped, the estimated delivery time depends on the shipping methods and Delivery destination. The table below shows are the logistic time for some common countries.

Delivery Cost

  1. Use your express account for shipment if you have one.
  2. Use our account for the shipment. Refer to the table below for the approximate charges.
(Different time frame / countries / package size has different price.)

Delivery Method

  1. Global Common Shipment by DHL / UPS / FedEx / TNT / EMS / SF we support.
  2. Others more shipping ways, please get in touch with your customer manager.

Common Countries Logistic Time Reference
Region Country Logistic Time(Day)
America United States 5
Brazil 7
Europe Germany 5
United Kingdom 4
Italy 5
Oceania Australia 6
New Zealand 5
Asia India 4
Japan 4
Middle East Israel 6
DHL & FedEx Shipment Charges Reference
Shipment charges(KG) Reference DHL(USD$)
0.00kg-1.00kg USD$30.00 - USD$60.00
1.00kg-2.00kg USD$40.00 - USD$80.00
2.00kg-3.00kg USD$50.00 - USD$100.00
Note:
The above table is for reference only. There may have some data bias for the uncontrollable factors.
Contact us if you have any questions.
  • QC (Quality Warranty)
  • Payment Support
  • Packaging
  • Certifications & Memberships

QC (Quality Warranty)

Allelco is committed to exceeding customer expectations through customer service excellence, order accuracy, and on-time delivery.
This is achieved through our commitment to the continual improvement of our processes, services, and products.


Strict quality inspection builds a solid foundation for electronic component quality.
  1. Visual inspection
  2. Performance testing and reliability verification
  3. Standardized full-process testing
  4. Precise control of every parameter
We eliminate defective components and ensure the stable operation of electronic devices through professional quality standards.

Payment Support

The payment method can be chosen from the methods shown below: Wire Transfer (T/T, Bank Transfer), Western Union, Credit card, PayPal.
  • HKBea
  • Paypal
  • MasterCard
  • Western-Union
  • VISA
Stable Delivery, Sincere Partnership — Your Faithful Supply Chain Partner
  • Efficient Supply Management
  • Cost-Saving Procurement
  • Fast Sourcing & Delivery
Contact us if you have any questions.

Packaging

Electrostatic Discharge Protection and Handling

All electrostatic-sensitive components are handled in accordance with electrostatic discharge control procedures. The products are hermetically sealed in anti-static safe packaging to prevent electrostatic damage. Appropriate labeling is also applied for identification and traceability. This ensures product integrity during storage, handling and transportation.


ESD

Certifications & Memberships

Third-party certified, strict quality control. Our certification
  • ISO 9001: 2015
  • ISO 13485: 2016
  • ISO 14001: 2015
  • ISO 28000: 2007
  • ISO 45001: 2018
  • GB/T 27922-2011
  • SMTA
  • IPC
  • ESD
  • PSMA
Honeywell Sensing and Productivity Solutions

LER00750TAMNKAAA15

Honeywell Sensing and Productivity Solutions
98D-LER00750TAMNKAAA15

Want a better price? Add to Cart and Submit RFQ now, we'll contact you immediately.

0 RFQ
Shopping cart (0 Items)
It is empty.
Compare List (0 Items)
It is empty.
Feedback

Your feedback matters! At Allelco, we value the user experience and strive to improve it constantly.
Please share your comments with us via our feedback form, and we'll respond promptly.
Thank you for choosing Allelco.

Subject
E-mail
Comments
Captcha
Drag or click to upload file
Upload File
types: .xls, .xlsx, .doc, .docx, .jpg, .png and .pdf.
Max file size: 10MB