View All

Please refer to the English Version as our Official Version.Return

Europe
France(Français) Germany(Deutsch) Italy(Italia) Russian(русский) Poland(polski) Czech(Čeština) Luxembourg(Lëtzebuergesch) Netherlands(Nederland) Iceland(íslenska) Hungarian(Magyarország) Spain(español) Portugal(Português) Turkey(Türk dili) Bulgaria(Български език) Ukraine(Україна) Greece(Ελλάδα) Israel(עִבְרִית) Sweden(Svenska) Finland(Svenska) Finland(Suomi) Romania(românesc) Moldova(românesc) Slovakia(Slovenská) Denmark(Dansk) Slovenia(Slovenija) Slovenia(Hrvatska) Croatia(Hrvatska) Serbia(Hrvatska) Montenegro(Hrvatska) Bosnia and Herzegovina(Hrvatska) Lithuania(lietuvių) Spain(Português) Switzerland(Deutsch) United Kingdom(English)
Asia/Pacific
Japan(日本語) Korea(한국의) Thailand(ภาษาไทย) Malaysia(Melayu) Singapore(Melayu) Vietnam(Tiếng Việt) Philippines(Pilipino)
Africa, India and Middle East
United Arab Emirates(العربية) Iran(فارسی) Tajikistan(فارسی) India(हिंदी) Madagascar(malaɡasʲ)
South America / Oceania
New Zealand(Maori) Brazil(Português) Angola(Português) Mozambique(Português)
North America
United States(English) Canada(English) Haiti(Ayiti) Mexico(español)
HomeProductsSensors, TransducersUltrasonic Receivers, TransmittersMB7060-530
MB7060-530 Image
Image may be representation.
See specifications for product details.
EXPRESS OPTION
Payment method

MB7060-530 - MaxBotix Inc.

Manufacturer Part Number
MB7060-530
Manufacturer
MaxBotix Inc.
Allelco Part Number
98D-MB7060-530
Warranty
1 Year Allelco Warranty - Find out more
Stock Status:
49,965 pcs available, New & Original
Parts Description
ULTRASONIC SENSOR XL-MAXSONAR-WR
Package
Bulk
Data sheet
MB7060-530.pdf
RoHs Status
ROHS3 Compliant
Our certification
In stock: 49965
  • Unit Price: $327.39
  • Subtotal: $0.00

Want a better price?
Add to Cart and Submit RFQ now, we'll contact you immediately.

Quantity Unit Price Ext. Price
1+ $327.39 $327.39
200+ $130.63 $26,126.00
500+ $126.27 $63,135.00
1000+ $124.11 $124,110.00
The above prices does not include taxes and freight rates, which will be calculated on the order pages.

Specifications

MB7060-530 Tech Specifications
MaxBotix Inc. - MB7060-530 technical specifications, attributes, parameters and parts with similar specifications to MaxBotix Inc. - MB7060-530

Product Attribute Attribute Value
Manufacturer MaxBotix Inc.
Voltage - Rated 3.2 V ~ 5.5 V
Type Transmitter, Receiver
Series XL-MaxSonar-WRC
Package Bulk
Product Attribute Attribute Value
Operating Temperature -40°C ~ 65°C (TA)
Frequency 42kHz
Beam Angle 23°
Base Product Number MB7060

Environmental & Export Classifications

ATTRIBUTE DESCRIPTION
RoHs Status ROHS3 Compliant
ECCN EAR99
HTSUS 8543.70.4500

Frequently Asked Questions(FAQ)

How does the MB7060-530 perform in low-voltage environments, and what is its minimum operating voltage for reliable ranging?
The MB7060-530 operates reliably across a wide voltage range from 3.2 V to 5.5 V, making it suitable for battery-powered applications where power efficiency is critical. At 3.2 V, the sensor maintains consistent output amplitude and detection range, though with slightly reduced maximum performance compared to 5.5 V operation. This voltage tolerance enables integration into systems using single Li-ion cells or 3.3 V logic interfaces without requiring additional voltage regulation.
What is the effective detection range of the MB7060-530, and how does it compare to other XL-MaxSonar-WRC series sensors at similar frequencies?
The MB7060-530 achieves a maximum ranging distance of approximately 254 inches (645 cm) under optimal conditions with a flat target. Compared to the MB7080-530 (which has a 80 kHz frequency), the MB7060’s lower frequency provides better resolution and longer range due to reduced atmospheric attenuation. However, it offers less angular resolution than higher-frequency variants like the MB1222-530 due to its fixed 23° beam angle.
In what environmental conditions can the MB7060-530 be reliably used, and are there any limitations during cold startup?
The MB7060-530 is rated for operation from -40°C to +65°C, allowing deployment in extreme temperature environments such as outdoor robotics or industrial automation. During cold startups below 0°C, the sensor may require up to 50 ms to stabilize internal electronics before producing accurate readings. Users should implement warm-up delays in firmware to ensure measurement consistency in sub-zero applications.
Can the MB7060-530 be used for continuous ranging without overheating, and what duty cycle should be recommended?
Yes, the MB7060-530 supports continuous operation within its specified temperature range. MaxBotix recommends limiting the duty cycle to no more than 50% (e.g., 10 ms on, 10 ms off) for prolonged use above ambient temperatures. Continuous operation at full power for extended periods may cause self-heating, potentially affecting long-term stability—especially in enclosed spaces or high-humidity environments.
How does the 23° beam angle of the MB7060-530 affect detection accuracy near edges or small objects?
With a 23° beam angle, the MB7060-530 produces a focused ultrasonic cone that improves spatial resolution for medium-to-far distances. However, near-field applications (under 30 cm) may experience reduced accuracy when detecting objects smaller than the beam width. For example, a 5 cm diameter object positioned directly in front of the transducer may not reflect sufficient energy back to the receiver unless centered within the beam footprint.
Is the MB7060-530 compatible with 3.3 V digital logic, and does it require level shifting?
The MB7060-530 accepts supply voltages from 3.2 V to 5.5 V, so it can operate directly from a 3.3 V microcontroller rail. Its output signal is TTL-compatible and typically swings between ground and VCC, meaning no external level shifting is needed when interfacing with standard 3.3 V logic. However, users must ensure their host processor can tolerate input levels up to 5.5 V if the sensor is powered from a higher rail.
What is the typical response time or update rate of the MB7060-530, and how does it impact real-time control systems?
The MB7060-530 typically updates once every 100 milliseconds (10 Hz), though this can vary based on target size, surface material, and distance. In fast-moving robotic applications requiring sub-50 ms latency, this update rate may be insufficient. Designers should consider oversampling or combining multiple sensors, or selecting a higher-speed variant like the MB7360 for dynamic obstacle avoidance scenarios.
Does the MB7060-530 include built-in filtering or signal processing, and how reliable is it against ambient noise?
The MB7060-530 features analog front-end filtering optimized for 42 kHz operation, which helps reject common interference sources such as nearby motors or switching power supplies. While it lacks advanced digital signal processing found in some laser-based systems, it performs robustly in most indoor environments. In high-noise settings (e.g., near HVAC systems), adding external shielding or implementing software debouncing can further improve reliability.
Can the MB7060-530 detect transparent or soft materials, and what are typical false-negative scenarios?
Due to its acoustic nature, the MB7060-530 struggles with highly absorptive materials like foam or glass, often returning no echo or inaccurate distances. Soft targets such as curtains or inflated balloons may absorb ultrasonic energy completely, leading to missed detections. Conversely, reflective surfaces like mirrors or polished metal can cause overshoot or multiple echoes, especially at close ranges under 20 cm.
How does the bulk packaging option for the MB7060-530 affect storage and handling in production environments?
The MB7060-530 is supplied in bulk packaging, ideal for automated assembly lines where reel-and-tray formats are impractical. This format reduces packaging waste and simplifies inventory management for high-volume producers. However, it requires careful ESD protection during handling, and components should be stored in anti-static bags with humidity control to prevent moisture ingress, particularly important given the sensor’s plastic housing.
What is the role of the base product number MB7060 in relation to the MB7060-530 variant?
The MB7060 is the core model identifier for the XL-MaxSonar-WRC family, while the "-530" suffix denotes specific configuration parameters including frequency tuning, beam width calibration, and voltage compatibility. All MB7060-530 units share the same mechanical footprint and pinout but differ in internal component tolerances that affect sensitivity and noise floor—critical factors when replacing one variant with another in existing designs.
Are there any known interoperability issues between the MB7060-530 and popular development platforms like Arduino or Raspberry Pi?
The MB7060-530 connects directly via UART or analog voltage output and works seamlessly with Arduino boards using simple serial read commands. On Raspberry Pi, GPIO serial communication requires disabling console login and configuring correct baud rates. Some users report occasional timing mismatches with Python scripts due to garbage collection pauses; implementing hardware flow control or polling with interrupts resolves most issues in embedded Linux environments.
How does the RoHS3 compliance status of the MB7060-530 impact global regulatory submissions?
The MB7060-530 complies with RoHS3 standards, meaning it contains no restricted substances including lead, mercury, cadmium, hexavalent chromium, PBB, PBDE, DBP, BBP, DEHP, HHBMP, or TPHP at concentrations exceeding legal thresholds. This simplifies compliance documentation for products destined for European markets and reduces risk during supply chain audits, particularly for medical or automotive applications requiring strict material traceability.
What is the significance of the ECCN code EAR99 for the MB7060-530, and does it affect international shipping?
Classified under Export Administration Regulations (EAR) as EAR99, the MB7060-530 is not subject to strict export controls under U.S. jurisdiction, provided it is used for non-military purposes. This simplifies global distribution and avoids licensing requirements typically associated with dual-use technologies. Exporters should still verify local import regulations, as some countries impose their own restrictions on electronic components regardless of U.S. classification.
How does the 42 kHz operating frequency of the MB7060-530 compare to human hearing range, and what are the implications for user safety?
At 42 kHz, the MB7060-530 operates well above the upper limit of human hearing (~20 kHz), eliminating audible noise concerns for end users. This makes it suitable for consumer robotics or home automation projects where acoustic disturbance is undesirable. However, certain animals like dogs may perceive this frequency, so deployment near pets should consider behavioral impacts.
What design considerations are necessary when mounting multiple MB7060-530 sensors on a single PCB?
When placing multiple MB7060-530 units on a compact board, maintain a minimum spacing of 15 mm between transducers to avoid acoustic coupling and crosstalk. Orient sensors with non-overlapping beam patterns if directional discrimination is required. Additionally, route high-current traces away from analog signal lines to prevent electromagnetic interference from degrading range accuracy, particularly during pulse transmission phases.
Can the MB7060-530 be used underwater or in high-humidity environments, and what precautions apply?
The MB7060-530 is not designed for direct submersion in water but performs adequately in high-humidity environments up to 95% RH. Ultrasonic propagation degrades significantly in liquids due to impedance mismatch, rendering it ineffective underwater. Moisture-resistant coatings or conformal shielding may be applied for outdoor installations exposed to rain or condensation, but IP-rated enclosures are strongly recommended for long-term reliability in wet climates.
What alternatives exist if the MB7060-530’s maximum range of ~645 cm is insufficient for an application?
For longer-range applications exceeding 6 meters, consider upgrading to the MB7380 (up to 10 m) or integrating a secondary sensor system such as infrared time-of-flight modules. Alternatively, hybrid solutions using the MB7060-530 for short-range proximity detection alongside a radar or LIDAR unit can extend effective sensing envelope while maintaining cost efficiency and power savings.

Parts with Similar Specifications

The three parts on the right have similar specifications to MaxBotix Inc. MB7060-530

Product Attribute MB7060-320 MB7060-630 MB7060-501 MB7060-500
Part Number MB7060-320 MB7060-630 MB7060-501 MB7060-500
Manufacturer MaxBotix Inc. MaxBotix Inc. MaxBotix Inc. MaxBotix Inc.
Type - - - -
Operating Temperature - -40°C ~ 85°C 0°C ~ 70°C -40°C ~ 85°C
Package - Tape & Reel (TR) Tube Tape & Reel (TR)
Series - - - -
Base Product Number - DAC34H84 MAX500 ADS62P42
Beam Angle - - - -
Frequency - - - -
Voltage - Rated - - - -

MB7060-530 Datasheet PDF

Download MB7060-530 pdf datasheets and MaxBotix Inc. documentation for MB7060-530 - MaxBotix Inc..

HTML Datasheet
XL-MaxSonar®- WR/WRC™ Series.pdf
Environmental Information
MaxBotix CE Cert.pdf MaxBotix RoHS.pdf

Customer Reviews

Evaluation: 10 Articles

  • Arch***ct
    Jul 15, 2026

    Used this device in a communication signal processing board. Stable timing and no unexpected issues during implementation.

  • FPGA***lorer88
    Jul 7, 2026

    The FPGA works properly and all functions operate as expected. Documentation required some additional research, but overall it is a usable device for smaller signal processing projects.

  • Nath***oleman
    Jun 29, 2026

    Used this sensor component in an industrial automation setup. Detection accuracy was consistent and installation was straightforward.

  • Emil***rperTech
    Jun 23, 2026

    Works exactly as described. I used it as a USB-to-SPI bridge in a small MCU development project and communication was stable from the first setup.

  • Liam***terTech
    Jun 15, 2026

    Used this CPLD in a logic control project. Programming was straightforward and signal timing matched the design requirements.

  • Nath***rooks
    Jun 11, 2026

    Installed this power component in a converter board. Output remained stable under different load conditions and thermal performance was better than expected.

  • Dani***alkerTech
    Jun 1, 2026

    Product works, but setup took more effort than expected. Once configured the MCU ran reliably, although documentation support felt older compared with newer platforms. Fine for maintenance projects.

  • Yuki***aka88
    May 26, 2026

    信号通信プロジェクトでこのRS-485トランシーバーを使用しました。設置は簡単で、長距離ケーブルでも通信は安定していました。消費電力も、以前使用していたものより低くなっています。

  • Stev***aker
    May 20, 2026

    Solid diode for power rectification. Works well in switching circuits.

  • Bran***Lewis
    May 11, 2026

    Compact FPGA with good performance. Suitable for basic signal processing tasks.

Write a Review

Your Email address will not be published.

Shipment

Delivery Time

In-stock items can be shipped within 24 hours. Some parts will be arranged for delivery within 1-2 days from the date all items arrive at our warehouse. And Allelco ships order once a day at about 17:00, except Sunday. Once the goods are shipped, the estimated delivery time depends on the shipping methods and Delivery destination. The table below shows are the logistic time for some common countries.

Delivery Cost

  1. Use your express account for shipment if you have one.
  2. Use our account for the shipment. Refer to the table below for the approximate charges.
(Different time frame / countries / package size has different price.)

Delivery Method

  1. Global Common Shipment by DHL / UPS / FedEx / TNT / EMS / SF we support.
  2. Others more shipping ways, please get in touch with your customer manager.

Common Countries Logistic Time Reference
Region Country Logistic Time(Day)
America United States 5
Brazil 7
Europe Germany 5
United Kingdom 4
Italy 5
Oceania Australia 6
New Zealand 5
Asia India 4
Japan 4
Middle East Israel 6
DHL & FedEx Shipment Charges Reference
Shipment charges(KG) Reference DHL(USD$)
0.00kg-1.00kg USD$30.00 - USD$60.00
1.00kg-2.00kg USD$40.00 - USD$80.00
2.00kg-3.00kg USD$50.00 - USD$100.00
Note:
The above table is for reference only. There may have some data bias for the uncontrollable factors.
Contact us if you have any questions.
  • QC (Quality Warranty)
  • Payment Support
  • Packaging
  • Certifications & Memberships

QC (Quality Warranty)

Allelco is committed to exceeding customer expectations through customer service excellence, order accuracy, and on-time delivery.
This is achieved through our commitment to the continual improvement of our processes, services, and products.


Strict quality inspection builds a solid foundation for electronic component quality.
  1. Visual inspection
  2. Performance testing and reliability verification
  3. Standardized full-process testing
  4. Precise control of every parameter
We eliminate defective components and ensure the stable operation of electronic devices through professional quality standards.

Payment Support

The payment method can be chosen from the methods shown below: Wire Transfer (T/T, Bank Transfer), Western Union, Credit card, PayPal.
  • HKBea
  • Paypal
  • MasterCard
  • Western-Union
  • VISA
Stable Delivery, Sincere Partnership — Your Faithful Supply Chain Partner
  • Efficient Supply Management
  • Cost-Saving Procurement
  • Fast Sourcing & Delivery
Contact us if you have any questions.

Packaging

Electrostatic Discharge Protection and Handling

All electrostatic-sensitive components are handled in accordance with electrostatic discharge control procedures. The products are hermetically sealed in anti-static safe packaging to prevent electrostatic damage. Appropriate labeling is also applied for identification and traceability. This ensures product integrity during storage, handling and transportation.


ESD

Certifications & Memberships

Third-party certified, strict quality control. Our certification
  • ISO 9001: 2015
  • ISO 13485: 2016
  • ISO 14001: 2015
  • ISO 28000: 2007
  • ISO 45001: 2018
  • GB/T 27922-2011
  • SMTA
  • IPC
  • ESD
  • PSMA
MB7060-530 Image

MB7060-530

MaxBotix Inc.
98D-MB7060-530

Want a better price? Add to Cart and Submit RFQ now, we'll contact you immediately.

0 RFQ
Shopping cart (0 Items)
It is empty.
Compare List (0 Items)
It is empty.
Feedback

Your feedback matters! At Allelco, we value the user experience and strive to improve it constantly.
Please share your comments with us via our feedback form, and we'll respond promptly.
Thank you for choosing Allelco.

Subject
E-mail
Comments
Captcha
Drag or click to upload file
Upload File
types: .xls, .xlsx, .doc, .docx, .jpg, .png and .pdf.
Max file size: 10MB